Manufacturer conversion and update behavior
Page 22 of the RX8900 application manual ETM45E-10 gives temperature in °C as (TEMP[7:0] × 2 − 187.19)/3.218. The data updates when the temperature compensation circuit operates. Reading the register does not itself trigger each conversion.
Preserve the code and calculation precision
Treat TEMP as an unsigned 8-bit value. Use floating point or sufficient fixed-point precision and retain the manufacturer constants. One code step corresponds to about 0.6215 °C. Raw 129 converts to approximately 22.004 °C, displayed as 22.00 °C after rounding. Display precision is different from update granularity and absolute accuracy.
Readings of 129, 129 and 130 may be normal discrete codes. Check operating conditions and the documented update mechanism before treating repeated reads as a communication fault.
| Item | Value | Limit |
|---|---|---|
| Conversion | (raw × 2 − 187.19)/3.218 | Keep manufacturer constants |
| Raw 129 | About 22.004 °C | Illustrative input |
| One code step | About 0.6215 °C | Different from accuracy |
| Repeated code | Check update mechanism | Insufficient to diagnose failure |
raw = 129 # Example input, not measured
temperature_c = (raw * 2.0 - 187.19) / 3.218
print(f"{temperature_c:.2f}") # 22.00Verify firmware and hardware separately
Use fixed inputs 0, 129 and 255 to check unsigned handling and avoid integer truncation. Boundary-code tests exercise arithmetic only and do not imply those temperatures are within the operating range. For board tests, record timestamps, raw bytes, converted data, configuration and an independent temperature reference.