An old 100 MHz differential clock is no longer supplied. A candidate is labeled LP-HCSL and matches the nominal frequency and package. The board still reads 100 MHz on the bench, but receiver amplitude changes and the edge can cross its threshold again. Compare the actual drive and termination diagrams. The traditional HCSL pull-down path and series damping do different jobs from LP-HCSL source matching. Integrated source termination can change which board components are appropriate.
Start with the four footprints
Renesas AN-879 illustrates traditional HCSL with 50 Ω from each line to ground and a series resistor near the driver to control ringing. Traditional variants can place the shunt at the source or the far end; the resistance alone does not describe the topology. Its LP-HCSL example combines about 17 Ω of driver impedance with 33 Ω series resistance per line to match a 50 Ω trace. Some devices integrate the series resistor. Confirm the exact variant and intended board impedance. An unpowered pin resistance measured in circuit is not a substitute for the manufacturer's diagram.
With an 85 Ω differential route, nominal single-ended impedance is about 42.5 Ω. Using the same 17 Ω example, an added 27 Ω gives 44 Ω. For a 100 Ω differential route, 17 plus 33 gives 50 Ω per line. Apply those examples only to the corresponding driver. Keeping 33 Ω on each leg after installing a driver that already presents 50 Ω can bring source impedance to about 83 Ω. An incoming reflection on a 50 Ω trace would reflect again at the source by about (83−50)/(83+50), or +0.248. This simple single-ended model is not an eye prediction. It shows why another series resistor is consequential.
Retaining a far-end load changes amplitude
AN-879 describes receivers with 100 Ω differential termination. Applicable LP-HCSL drivers can work with both ends terminated, at a smaller swing. In an ideal divider, two 50 Ω source impedances present 100 Ω differentially. A 100 Ω receiver then sees about half the open-circuit voltage. An assumed 1.6 V peak-to-peak differential source gives about 0.8 V. More board or instrument loading also affects common mode and swing. Record differential peak-to-peak, single-ended levels and common mode separately.
If the old PCB has two 50 Ω pull-downs and the receiver adds an internal 100 Ω differential resistor, the pull-down pair appears as 100 Ω in differential mode. In parallel, the resulting differential load is about 50 Ω. In the same ideal 100 Ω source model it receives only about one third of open-circuit swing. Draw board parts, receiver settings and fixture loading together. Keep or remove termination based on receiver and source requirements. An AC-coupled design also needs an intentional DC and bias path on the applicable side of the capacitors.
Compare both assemblies under the actual conditions
Capture the old board at the receiver, then populate the candidate's documented termination without changing the route or consumer. Use suitable differential probing or a characterized fixture that does not add an accidental DC load. Verify first pulse, ringing and receiver lock across intended voltage, temperature and power modes. If termination is programmable, retain register readback and the physical resistor population. Specify trace impedance, internal or external source matching, receiver load and swing with the 100 MHz LP-HCSL sample. Release the population based on the receiver waveform and actual function.
A board can have equal resistor values with different physical placements. If one is beside the driver and another beyond a connector or long trace, the path between resistor and driver is electrically significant. Mark spacing, pair balance and return paths in the actual layout. Change one item at a time on an engineering sample so a successful automatic relock cannot stand in for a termination result.
Capture both wires simultaneously to calculate differential and common-mode voltages. Subtracting two independent captures can move the crossing through trigger and instrument skew. Verify the probe channels with a common input, then test minimum pulse widths near the receiving pin. Match supply, temperature and receiver configuration. Document any change in probe or timebase separately.
For both a short PCB route and a cabled option, exercise each approved receiver population. A quiet result on one cannot predict reflections on the other. Keep time to first valid reference separate from repeat crossings during steady operation. Also document the active output count and real load when comparing power. Use a separate measurement for disabled outputs.