Why is DS90LV028A output high after a 100 MHz LVDS clock is disconnected?

A 100 MHz LVDS crystal oscillator sends a clock across a cable. On the receiving board, a DS90LV028A translates it to single-ended logic. The output stays high after unplugging, and a host clock-ready input that treats high as healthy reports no fault. A static level and a continuous clock need different tests. Fail-safe behavior assigns an output state under specified conditions.

Identify the actual input condition

TI specifies open, terminated-undriven, and conditional shorted fail-safe behavior for the DS90LV028A. A point-to-point cable usually has a 100-ohm termination across the receiver inputs. When the driver is disconnected or powered off, the output can still be high. The shorted condition applies with the inputs joined and no external common-mode voltage. TI does not extend shorted fail-safe to the normal receiver's full common-mode range. One artificial short does not exercise every field condition.

Disconnecting the cable at the receiver removes the cable from its inputs. Disconnecting at the far end leaves a cable attached to the receiver. The remaining cable can pick up differential noise. TI notes that more than 10 millivolts of differential noise on such an undriven cable may cause switching. An isolated output edge is therefore insufficient evidence that the oscillator restarted. Capture both unplugging conditions at the receiver with representative neighboring circuits active.

Estimate differential and common-mode bias

Use the data sheet's resistor guidance and TI AN-1194 if external fail-safe bias is needed. As a first-order undriven example, use 5 kilohms from a 2.5-volt bias supply to the positive input and another 5 kilohms from the negative input to ground. Keep the 100-ohm termination across the pair. Neglecting receiver leakage and internal bias, 2.5 volts divided by 10,100 ohms gives about 247.5 microamps. The termination then develops about 24.75 millivolts of positive differential bias, with a common mode around 1.25 volts. The data sheet calls for an external bias around 1.2 volts and below 1.75 volts common mode.

The estimate describes the undriven DC case. When the 100 MHz LVDS crystal oscillator resumes driving, the network also affects the active link. Measure normal and stopped common mode, differential amplitude, and receiver performance. Compare disturbance levels with the required bias margin and use measured results at the intended corners. Verify the termination population as well. An unintended second termination changes the measured swing and can be mistaken for a bias effect.

Require continuing edges to qualify the clock

A 100 MHz LVDS crystal oscillator has a 10-nanosecond period. An independently timed one-microsecond window nominally contains about 100 edges of one polarity. Allow for gate alignment when setting limits. A static high output gives no continuing period once unplugging transients have passed. Check edge counts and, if required, the longest gap. A single edge could be caused by a reconnection transient or interference. Set the observation window and allowed gap from how quickly the system needs to stop using the reference.

Start acceptance with the source and cable installed. Verify frequency and receiver swing. Keep termination in place while powering off the source and unplugging the remote end. Check both receiver fail-safe behavior and the host's clock-loss indication. Reconnect and record when a valid clock returns and when the host resumes operation. If some units still switch intermittently without a source, investigate cable balance, termination, and interference before changing the bias. Keep the receiver's exact part number in the qualification record because a pin-compatible alternative can define fail-safe conditions differently.

If the detector itself runs from the clock being monitored, it may stop updating when the source stops. Identify which independent timebase declares the timeout and which logic reports it. Where an accumulated count crosses a clock-domain boundary, check that the implementation reads it consistently. Disconnect at several relative phases and measure detection delay from the first missing edge. Verify actual system behavior alongside the level at the receiver.

A brief reconnection can produce a few transitions followed by another interruption. As an example, requiring two consecutive one-microsecond windows with stable counts gives at least two microseconds of observation when aligned. Include the wait to the next full window when estimating detection time with an independent reference. Record the interruption or connection, the continuous edge trace, and the host state. These three records distinguish early alarm clearing from switching near the fail-safe threshold.

After increasing bias, repeat the running-clock test. Added bias can change edge crossing times as well as improve the undriven differential margin. Use the same fixture and termination in both tests. If output duty cycle falls outside the downstream device's requirement, review the bias, cable, and receiver conditions together.