A high-speed board uses a 100 MHz reference for the AD9467. The differential sampling input is correct, but the digital DCO measures about half that frequency. Before diagnosing 50 MSPS conversion, check whether the output uses both clock edges. The sampling clock establishes the conversion cadence. A slower forwarded data clock can deliver one word on each edge. A rising-edge-only receiver can report half the intended throughput even with the oscillator and ADC working.
Count complete results per second
ADI specifies double-data-rate capture using both rising and falling DCO edges. At exactly 100 MHz sampling, the ADC produces 100 million results per second. Two results per forwarded clock period correspond to nominal 50 MHz DCO. Its period is 20 ns and the edges are nominally 10 ns apart. The sixteen bits arrive on a parallel differential interface. The receiver still needs the specified capture relationship. Saving only rising-edge results gives 50 million words per second and loses half the conversion sequence. Increasing the oscillator frequency does not recover the ignored edge.
If receiver logic passes results into another domain as pairs, define the rising and falling member order. Reversed pairs keep the same long-term throughput and still corrupt the sequence. Adjacent samples nominally 10 ns apart on a 10 MHz sine differ in phase by about 36 degrees. Swapping them need not resemble a uniform time delay. Restore order before attributing the result to frequency error.
Preserve the forwarded timing relationship
ADI provides DCO-to-data delay limits and a timing diagram. Another 50 MHz clock can share the same source without reproducing the ADC's output phase. Capture using the received DCO, then cross into the processing domain as appropriate. Budget both differential pair balance and relative data-to-clock arrival across pairs. Use the FPGA input timing, board conditions and shortest relevant window on both edges. Equal pair lengths establish only one part of the path.
The device has a DCO inversion setting that can help isolate pairing assumptions. It changes which external edge is called rising. It does not fix arbitrary signal integrity failures. Change one setting at a time, read back the effective configuration and compare a sequence that identifies both members. A static all-high or all-low pattern cannot reveal sample order.
Verify patterns and real conversion separately
The data sheet includes checkerboard, alternating-word and pseudorandom patterns. Use active transition patterns and a traceable start to check bit and edge assignment, then run a longer test with the applicable pattern and initial state. Some patterns have their own coding conventions independent of analog data format. Decode accordingly. Disable the pattern before testing a known analog stimulus and timestamp. A passed digital pattern does not establish front-end performance, clock phase noise or analog drive quality.
Document the 100 MHz oscillator's coupling to the sampling pins, the received DCO period, word width and member order. If delay matters, retain pipeline cycles and host crossing and processing time separately. Confirm the timing with a repeatable input marker. After a sample-rate change, check when clock timing, digital capture and analog data each become valid. The first toggling DCO is not sufficient evidence for the first useful application result.
Read the switching parameters before calculating a capture window. Table 4 gives a DCO-to-data skew limit of ±200 ps under the stated test conditions. That magnitude is about 2% of the 10 ns interval in the example, and covers one part of the transmitter uncertainty. Calling the other 9.8 ns FPGA margin would ignore the chosen capture phase, PCB path differences, and receiver timing. List earliest and latest data arrival for each capture edge in the timing report and include any board-specific delay or phase adjustment. When checking on an oscilloscope, measure data and DCO at equivalent points so that fixture differences do not masquerade as PCB skew.
The same table lists a pipeline latency of sixteen sample clock periods. At 100 MHz that is 160 ns for this fixed-cycle part of the path. A new result can still appear every 10 ns. To align timestamps with a second measurement board, start with a repeatable analog event and record its time against a common reference. Check the arrival of the corresponding sample word, the application logic, and the recorded output separately. A correct sample count detects some dropped data but cannot catch a systematic timestamp offset. Those measurements support any change to the timestamp insertion point.