Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Measurement and Acceptance

Acoustic noise adds sidebands to a 10 MHz OCXO. How can you separate airborne sound from base vibration?

A noise source inside an enclosure adds sidebands around a 10 MHz OCXO carrier. Base isolation pads make little difference. Air pressure can excite the enclosure, and the same motor can put a spur on a supply. Mount the acoustic source independently, and record sound pressure, acceleration near the oscillator and output phase together. Compare with a second run under the actual mechanical mounting.

Separate the sound source from the product's supply and support

IEC 60068-2-65:2013 describes procedures for testing acoustically induced vibration under defined sound-pressure conditions. It does not set a phase-noise limit for a particular oscillator. For a diagnostic test, put the unit on a defined support and use a calibrated loudspeaker or chamber source with its own support and supply. Record background, then apply the approved levels, directions and frequencies. Use the laboratory's enclosed equipment and operating limits when high sound pressure is involved.

Place a calibrated microphone near the OCXO and measure acceleration at a relevant point on the case or board. Use a low-mass sensor or permitted noncontact method so that the measurement does not significantly shift a structural mode. Put the reference oscillator outside the acoustic and thermal environment of the unit. Strain-relieve the RF leads and avoid rearranging them between tests.

Record the quiet background first, then drive a narrowband acoustic tone under the same mounting conditions. Log both the source drive and microphone. Local pressure can differ from the speaker rating or average room pressure. Keep the product motor off during this comparison to remove its direct supply and support paths. Where the facility allows, leave the speaker amplifier running with the acoustic path blocked and observe whether sidebands remain, which helps identify electrical or shared-rack pickup.

Measure phase response against a shared time reference

NIST describes vibration and acoustic sensitivity that can appear as modulation sidebands in oscillator measurements. Verify with a phase measurement that the sidebands are predominantly phase modulation and check the amplitude channel too. Two similar sidebands on a spectrum are insufficient to distinguish AM from PM. Capture acoustic drive, pressure, acceleration and carrier phase together so their magnitude and phase at the stimulus frequency can be compared.

Try two levels at the same tone, such as 100 and 106 dB SPL. Using the airborne reference of 20 μPa, these correspond to approximately 2.00 and 3.99 Pa RMS, a near doubling. These values refer to the microphone at the product. Amplifier gain is not a substitute for local pressure because of enclosure standing waves. Recheck both levels if the microphone moves.

Suppose the 10 MHz OCXO produces verified small-angle PM sidebands of −70 and −64 dBc per side. Peak phase deviation is approximately twice the sideband-to-carrier voltage ratio. The figures give about 0.000632 and 0.001262 rad. Dividing by two pi times 10 MHz gives peak timing deviations of approximately 10.1 and 20.1 ps. An allowance of 15 ps peak for this discrete component passes at the lower level and fails at the higher level. The estimate assumes predominantly PM and is distinct from integrated broadband jitter.

Modify one path and retest the installed product

For the acoustic control, keep the wiring and supply intact and vary sound direction. Check whether equal local pressure reproduces the phase sideband. Then turn the speaker off and apply mechanical excitation in an approved vibration fixture, logging acceleration at the same point and orientation. Microchip describes oscillator PM arising from acceleration sensitivity. Both stimuli can strain the enclosure. Compare pressure, structural motion and phase rather than treating them as unrelated quantities.

If a sound cover reduces local pressure and the phase sideband while monitored acceleration barely changes, give the acoustic path priority. If phase follows base acceleration, inspect the supports and mounting. A sound cover can also change airflow and temperature, so capture local temperature as a control. Record supply disturbance separately to keep an electrical spur from being mistaken for an acoustic one.

Qualify a replacement oscillator in production-representative assembly and sound conditions. Record pressure level, discrete frequency, local acceleration direction, phase sideband and temperature. A typical acceleration-sensitivity number alone cannot predict the response of the specific enclosure to sound. A candidate 10 MHz OCXO has a defensible substitution case if it reproducibly reduces the sideband under those conditions and also meets the regular frequency and electrical requirements.

If the result depends strongly on one enclosure frequency, maintain pressure and take a few points on either side while observing structural phase response. If the peak moves after changing the housing, keep a matching assembly as a control so an enclosure mode is not assigned to an oscillator lot. A validated sensitive frequency can support sampling inspection, while design qualification still covers other acoustic sources and assembly variants in the test plan. Record microphone location and orientation at each point for repeatability.

References

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.