Pull SYNCB low on an AD9515 and one clock pauses while the other keeps running. Before inspecting the sync connection or suspecting a missing edge from the 10 MHz OCXO, check both divider settings. A bypassed divider changes how its output responds to the same command. Moving that output to a controlled divide setting makes a direct bench comparison.
Check the scope of synchronization
The AD9515 data sheet applies SYNCB to enabled outputs whose division ratio is greater than one. They enter a state set by the divider and phase settings and resume after synchronization releases. At divide by one, the output bypasses the divider and follows the input with propagation delay. Programmable delay, receiver threshold, and output type can change observed skew. Identical scope crossings are therefore not a test that synchronization acted correctly.
The 10 MHz OCXO in this example drives CLK through a suitable buffer, coupling network, and termination under the data sheet input conditions. Verify steady operation against an independent reference before attaching the test circuit. The input period is 100 ns. In divide by two, one output has a 200 ns period. The bypass output keeps a 100 ns period. The electrical standards on the two outputs may differ. Match each probe and termination to its interface, and confirm whether low amplitude originates at the load or in the measurement.
Count input periods after the command
Probe SYNCB, the clock input observation point, and the two receiver nodes. Send an active-low synchronization pulse and verify the data sheet minimum low duration of 5 ns at the pin. Use margin in the bench stimulus. If the command generator and input clock are asynchronous, record their relative phase and compare repeated events with similar alignment. The programmed generator width alone does not establish what arrived at the device.
The documented recovery timing uses input-clock periods. Four periods at 10 MHz amount to 400 ns. Counting four periods of the divide-by-two output would mistakenly give 800 ns. Use four input periods to interpret the timing diagram, then locate the first output edge under the selected phase setting. The output phase, alignment of release to CLK, and propagation can change the observed first edge. The 400 ns figure is not a universal bound to the first terminal transition.
Capture full periods before and after the command. On a stable bypass output, each 100 ns rising edge should pair with an input edge throughout the window. The divided output shows a holding interval before returning to 200 ns spacing. Scope averaging can smear the first edge when its placement differs between captures. Inspect individual records before deciding whether a genuine input cycle was missed.
Put the bypass path into divide by two for comparison
Keep the supply, 10 MHz OCXO, and sync pulse fixed. Set the formerly bypassed output to divide by two according to the configuration table, recording phase and delay settings for both outputs. Repeat the pulse and see whether the previously continuous path now pauses. If the application supports issuing SYNC before the input returns, verify that separately. Keep the clock-present and clock-absent sequences in separate records.
If both are set to divide by two and only one holds, check actual setup-pin voltages, phase settings, and whether the output is disabled. A digital probe showing high or low cannot verify the intermediate programming levels. If the bypassed output pauses, check whether an external circuit interrupted the input. If both are quiet, measure input coupling, load, power, and observation bandwidth to distinguish absent clock from insufficient amplitude.
Record the restored relative phase separately. Even with confirmed zero phase offset, different electrical paths can introduce propagation skew. Use a shared calibration edge to measure the two probe paths. Repeat at different release phases. A fixed skew within the board budget is consistent with propagation. A difference in steps of 100 ns calls for renewed checks of divider phase and sync-to-input alignment.
If the scope shows overshoot only around synchronization, retain a second observation point before the receiver and reference both points to the same input edge. The held level depends on the divider and phase. Evaluate active transitions and any false counts at the receiver instead of assigning a fault from the held level alone.
If the application requires all receivers to stay quiet during synchronization, test the actual gate that enforces that behavior. Keep the settings fixed when changing the 10 MHz OCXO and verify operating frequency, input continuity during SYNC, divided output state, and phase on recovery. If both oscillators behave alike in bypass, revise the acceptance criterion. Investigate a reference or interface change when missing input cycles track the sample.
