A 10 MHz OCXO works on the bench supply. Why does the filtered converter oscillate in the product?

A 10 MHz OCXO is stable when powered directly on the bench. In the product, input and output of its buck converter oscillate slowly below rated power, and clock sidebands appear. Check the interface between input filter and converter. At some frequencies the filter can have high output impedance while a regulated switcher can present negative incremental input impedance. DC headroom or an oscillator replacement alone may miss the interaction.

Identify which node starts to move

Capture the bus before the filter, converter input, OCXO supply at its pins and relevant current or controller state. Use one timeline for input ringing, oscillator enable, heater load changes and clock disturbance. Compare warm-up and steady operation. Some faults occur only at the higher-power point. If the input stays clean and output moves first, investigate local feedback, current limiting and load. If ringing starts downstream of the input filter, check the input network.

TI explains that some converters draw less current as input voltage rises over a range where regulation holds power nearly constant. Negative incremental resistance describes the small-signal slope about a working point. It is different from DC voltage divided by current and is not a general property of the OCXO itself. Verify the installed converter and actual load. Input impedance can change as the oven warms or the converter moves between modes.

For an isolated supply control, disconnect the normal supply output before connecting the 10 MHz OCXO to an approved independent source. Retain the ground reference and clock termination. Apply a representative load to the original converter for a separate test. Continued input oscillation with an equivalent steady load weakens a unit-level explanation. If it occurs only during warm-up, capture the real load trajectory and reproduce it with suitable equipment.

Retain magnitude and phase in the small-signal measurement

Use an injection setup rated for bus voltage and current. TI's power supply seminar shows how a current injector and frequency response equipment can measure filter output impedance. At the actual filter-to-converter plane, measure towards each side using the appropriate DC operating configuration. Calculate complex impedance from the measured voltage and current perturbations. Check the fixture for resonances from injection equipment, probes or temporary wiring.

Compare peaks in the sweep with the ringing frequency under ordinary load. Keep perturbation small enough to avoid bypassing the operating point through protection, burst transitions or current limiting. Record converter mode. During rapid warm-up, consecutive sweep points may represent different conditions. Recreate a representative load condition or measure selected frequencies. A magnitude crossing calls for checking phase and load response. It does not prove instability by itself.

Estimate the impedance from the input power

Suppose a 12.0 V input draws 6.0 W in a nearly constant-power operating region. Negative voltage squared divided by power gives an incremental resistance estimate of −144 ÷ 6.0 = −24 Ω. Compare against measured small-signal current under an approved voltage perturbation. Where its magnitude or phase disagrees, do not use the constant-power approximation to decide.

Suppose the filter peaks at 26 Ω while converter input impedance magnitude is 24 Ω. The ratio is about 1.08, or +0.70 dB. After damping, a 3.0 Ω peak gives a ratio of 0.125, about −18.1 dB. Use magnitude to locate the frequency of concern, then evaluate complex phase and actual ringing in the same state. The result is specific to that load condition.

Preserve the product's electrical and clock requirements after rework

Try a properly rated damping network on an engineering sample where permitted. With the original wiring, remeasure input peaking, output ripple and clock sidebands. If bypassing the filter was useful for diagnosis, the final assembly must still satisfy the project's conducted emission and power requirements. After changing the supply or capacitor, verify low-line startup, maximum heater demand and high-temperature operation.

Record supply path, injection plane, OCXO operating stage and the corresponding carrier and sidebands on original and candidate boards. After verifying power stability, compare oscillator response to the same remaining supply ripple. If both ripple and sidebands disappear after a supply change, record it as a power-network correction and verify repeated startup and steady operation in the product.

Repeat with the original supply harness length and see whether the filter peak follows the harness. Long cables and input capacitance can form another resonance. Passing with short bench leads does not qualify the installed harness. Before changing remote sensing or paralleling supplies, check the source's wiring and feedback requirements.

Where permitted, record complex impedance at both minimum and nominal bus voltage. At equal power, lower input voltage reduces the magnitude of the negative incremental resistance. Include actual input power and converter mode so there is a comparable reference for a replacement power module.