Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Measurement and Acceptance

Why did replacing the tuning voltage source raise close-in phase noise on a 10 MHz OCXO?

Two 10 MHz oven-controlled oscillators can both be trimmed to the required frequency. One uses a quiet DC divider and the other uses the product's DAC. The second trace is noisier near the carrier. Frequency adjustment establishes the mean control voltage. Small random variations at the tuning input can still disturb phase. Separate the tuning source contribution from intrinsic oscillator behavior before judging a substitute.

Start with measured gain and voltage noise

Microchip's OX-224 provides fixed and tunable options. The data sheet specifies the electronic frequency control voltage range and positive slope and describes a reference divider in relevant stability test conditions. Match the option to the intended wiring. Tuning span across the full range does not establish small-signal slope at a particular voltage. Use a small allowed step near the working point and record the measured pin-voltage change and settled frequency change in hertz per volt.

Suppose a 10 MHz OCXO measures 2 Hz/V near its working point, and the single-sided control voltage amplitude spectral density at ten hertz offset is 2 microvolts per root hertz. Frequency noise is about 4 microhertz per root hertz. Dividing by ten hertz gives phase-noise amplitude density of about 0.4 microradian per root hertz. Phase integrates frequency fluctuation. The example assumes small signals and a tuning response close to the measured DC slope at that offset.

Square the phase amplitude density, divide by two for the single-sideband ratio, and express it in decibels. The result is about −131 dBc/Hz. If both control voltage noise and tuning gain remain flat at 100 Hz offset, its contribution is about −151 dBc/Hz. Analog Devices describes this slope for flat noise entering a tuning input. The example estimates one path. It does not include intrinsic noise or closed-loop behavior.

Match the actual pin bias for both voltage sources

Measure the original circuit under constant warm-up and load. Record mean pin voltage, phase noise, DAC update mode, and loop state. Substitute a verified low-noise source using the permitted isolation and bias conditions. Refer voltage to oscillator ground and confirm its loaded value. A large mean frequency change suggests a different tuning region or driver drop. The cleaner spectrum alone does not then isolate noise from the DAC.

An amplifier or scope connected to the tuning node adds its own noise, capacitance, and ground path. Check measurement background using an appropriate short or quiet source, then change the sensing arrangement if needed. Document spectral-density units. A broad-band peak-to-peak number cannot replace voltage density. Regular update activity can make a discrete spur, which calls for its measured offset and tone level rather than a white-noise calculation.

Check what the loop does to each path

The tuning port often belongs to a slow phase lock or calibration loop. A fixed-bias test characterizes free running. Closed-loop operation can suppress some slow variation and pass reference or control effects. Compare fixed bias and normal operation in the supported modes and record loop settings and driver. If disabling updates removes one spur while a wider rise remains, investigate analog bias noise or the instrument path as well.

Supply noise can affect both driver and oscillator. Leave oscillator power unchanged while testing the control port and align the relevant captures. Where practical, exchange original and candidate oscillators against the same quiet source. If the trace follows the bias driver, investigate operating conditions. If it still follows the device with verified bias, temperature, and warm-up, compare it with the oscillator specification.

Include close-in noise in the substitution decision

For a replacement 10 MHz OCXO, local tuning sensitivity matters along with static range. Two parts can cover the required span and differ in gain near the operating point. Higher gain converts the same voltage density to more phase noise. Retain bias, slope, voltage noise at relevant offsets, and comparable phase noise. If filtering reduces noise, recheck calibration response and recovery with required control behavior enabled.

When combining the estimate with intrinsic phase noise, add linear power spectral densities if the sources can be treated as uncorrelated. For example, a verified fixed-bias result of −138 dBc/Hz and a tuning contribution of −131 dBc/Hz combine to around −130.2 dBc/Hz. Adding the two decibel numbers would be invalid, and choosing the larger gives only an approximation. A shared reference or driver can introduce correlation, so confirm the actual setup.

The budget can also constrain allowed voltage noise. At a ten-hertz offset and 2 Hz/V, halving the voltage amplitude density reduces this contribution by about six decibels. Give the control designer the target band with the verified oscillator baseline. Where tuning response declines at higher offsets, use the measured transfer instead of the DC slope.

Record the bias source's ground reference and the actual sensing point for each comparison.

References

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.