A synchronized device transfers to backup power. Its 10 MHz oven-controlled oscillator continues producing a clock. Frequency temporarily rises, falls, and returns to its original value. A steady-state comparison records no final offset. The receiver has already counted extra or missing cycles along the way. If the system limits time error during transfer, preserve both the maximum excursion and the final result using continuous phase or frequency records.
Distinguish steady pulling from the transition
NDK explains that supply changes can temporarily affect oven temperature and cause frequency overshoot or undershoot before recovery. Check actual limits and behavior for the complete part. Final frequency difference, peak transient, and accumulated cycles describe different quantities. Returning to the earlier frequency returns the phase slope. It does not erase an existing phase shift.
Warm up the 10 MHz OCXO and hold environment, termination, and tuning input constant. Use independent reference for continuous phase and save device voltage and current alongside it. Keep voltage inside the specified range. Complete power removal needs its own dropout and restart test. Record long enough to see the new plateau and the response when returning to the original voltage.
Convert the area under frequency into time error
Suppose a stable reference establishes a baseline. The disturbance is approximately triangular over thirty seconds with a positive peak of 0.080 Hz. Its area is thirty times 0.080 divided by two, about 1.20 extra cycles. At 10 MHz each cycle lasts one hundred nanoseconds, giving about 120 ns of phase advance. That lead can remain after frequency has settled.
Suppose another thirty-second triangle reaches −0.040 Hz. Its negative area is about 0.60 cycle. If the events are separate, final advance is about 60 ns, with an earlier peak of 120 ns. A 100 ns maximum during switching would be missed by testing only the last value. Integrate actual samples with their timestamps or use continuous unwrapped phase. Keep sign and reference conventions consistent.
Keep the reference out of the disturbance
If power transfer affects the comparator or reference, its phase can enter the result. Power both separately and check a common-source baseline. Repeat the disturbance with a known independent signal still using the original measurement path. If switching affects trigger level, retain clock amplitude, phase, and instrument state. A temporary amplitude change should not appear as a timing step.
Avoid exporting only phase modulo one cycle. The example exceeds one turn. Check phase unwrapping and mark loss of lock, acquisition gaps, or repeated starts. Do not draw a smooth integral across missing samples without evidence of continuity. Acquire again using a continuous phase path or mark the interval unusable.
Save peak, recovery, and reference for substitution
Compare both 10 MHz OCXOs with identical voltage and reset sequencing. Keep voltage at the device, maximum phase deviation, and time to stable operation. If short successive transfers are allowed, repeat at that interval and look for accumulation. If final frequency agrees and the candidate has a larger transient, verify supply and thermal conditions before applying the system timing budget.
On one time axis mark when voltage becomes acceptable, when frequency settles, and when phase reaches its extreme. These conditions can occur at different times. Any requirement to realign after a residual time shift belongs in the system acceptance definition.
Define the pre-transfer frequency baseline. In the sixty-second example, an error of 0.010 Hz in the removed baseline changes the integral by 0.60 cycle, or 60 ns. That matches the scale of the final residual. Record enough undisturbed time, short-term drift, and reference quality. A product budget referenced to nominal may include that baseline error. Remove a pre-existing trend only when estimating the separate contribution of the transfer, under a stated method.
The rail can break before making contact or ramp gradually after transfer. Inspect voltage and current and repeat the opposite direction. Thermal history can make equal steps give unequal peaks. Establish cancellation from continuous data. If a system time correction occurs, mark it so the resulting phase step is not mistaken for natural oscillator recovery.
Archive the before-and-after waveforms, the rail step marker and the time of peak error together. A revised board filter may appear to improve the oscillator simply by slowing the rail edge seen at its pins. Repeat the test with the same measured input step before attributing a reduction in accumulated error to the filter, supply path or replacement part.