Does one pulse per second let a 10 MHz OCXO counter synchronize to ZED-F9T?

A timing terminal counts with a 10 MHz oven-controlled oscillator and uses ZED-F9T TIMEPULSE to mark seconds. Soon after power-up, the display reports one pulse per second. Software immediately marks local time valid. Reliable satellite time becomes available later, and the stored boundaries then need realignment. The local oscillator measures intervals. The GNSS module applies its own conditions before supplying an edge aligned to the chosen time scale. A working pulse repetition rate does not establish that the synchronization condition has been met.

Identical repetition rates can indicate different timing states

The u-blox integration manual allows distinct period and pulse-width settings depending on whether valid time is available and alternate settings are selected. Its own example retains 1 Hz in both states, while alignment to the GPS second is maintained only when GPS time is locked. Counting edges once per second cannot distinguish those states. Read back the active pulse definition and verify configuration persistence after a genuine power cycle. A transient setting used at the bench may differ from the next cold-start configuration.

As an illustrative implementation, set the high interval to 40 ms before lock and 200 ms after lock, while keeping a one-second period in both cases. Select length units and distinguish time from duty percentage. Both states produce roughly sixty rising edges per minute. Capture the rising and falling edges of each pulse with the local counter. At nominal 10 MHz, one OCXO cycle lasts 100 ns, so the two widths correspond to about 400000 and 2000000 counts. Allow for propagation, capture uncertainty, and state changes when defining acceptance windows. These numbers describe width classification and do not establish absolute timing accuracy at 100 ns.

Use the appropriate edge for the boundary

When the rising edge defines the second, the falling edge closes the width measurement. Before it arrives, the width cannot classify the current pulse. Save the rising-edge counter value and its sequence number, then decide whether to commit after classification. If the downstream program instead timestamps the falling edge, switching from 40 ms to 200 ms moves its record by 160 ms relative to the intended marker. That difference comes from the selected edge, independently of oscillator accuracy. Changing polarity also changes which physical edge marks the start and end of the active pulse.

Handle state transitions explicitly. A clipped pulse around the transition is poor evidence for reassigning system time. A recovery policy can require consistent subsequent state and verify the module's documented time validity and selected time grid. The time grid determines the time scale of the pulse and related information. A correct width does not establish that a host has interpreted the right time scale. Save polarity, active time grid, and module state beside the capture.

Verify the local reference and the external validity state

In normal reception, capture the cold start and compare pulse widths, period and reported state through valid timing acquisition. Then exercise the product's supported loss and restoration condition. Check when the local software stops and resumes moving its time against TIMEPULSE. The integration manual gives a minimum high and low interval except when deliberately disabling the output. Choose widths the receiver reliably captures. If the controller sleeps through a falling edge, mark that width unknown rather than pairing a rising edge with a later pulse.

After substituting the 10 MHz OCXO, verify the received frequency, voltage, and warm-up conditions. Repeat the unlocked-to-locked transition and verify both width categories and the edge actually committed as the boundary. Also retain per-second count deltas beside the module status when analyzing local frequency. A complete record separately establishes that the new reference fits the counter circuit and that the application handles the changing status of the GNSS pulse.

A fixture can deliberately miss one complete edge pair to check gap handling. If two captured pulses are separated by more than the expected period, report the missing observation according to the application instead of calling the whole interval one long local second. A diagnostic view can show the captured count, measured width and acceptance result together.

Also distinguish the receiver's output time from the time the host processes its serial message. A periodic task may read status one cycle later. Pair timing messages and hardware captures according to the device's documented association and preserve their identifiers. Message arrival time should not replace the pulse timestamp. The original edge pair can still be retained even when messages are queued.