A fine tuning step leaves the 10 MHz SiT5356 counter display unchanged. How can you verify it?

A small digital frequency correction is sent to a 10 MHz SiT5356 TCXO, but the counter shows the same last digits. Calculate the expected change in hertz first. A larger known step can validate the command path. A continuous phase record can resolve smaller changes in slope. An unchanged display alone cannot distinguish a failed write from insufficient measurement resolution.

Separate tuning range from resolution

SiTime specifies power-up nominal frequency and pull range by ordering code, with digital adjustment available during operation. Pull range defines permitted excursion. A separate table gives fractional frequency resolution, including 5 × 10⁻¹² for a ±25 ppm pull setting. Resolution describes how finely the device can be set. Absolute accuracy, bench uncertainty and measured adjacent-code response require their own evidence.

The manual also specifies writing the lower word before the upper word, with the last write initiating the change. Verify device configuration and log both words, any readback and the timing. Retain raw codes and pull range in the fixture log. If power-up restores the order-code setting, check whether the host reapplies the required correction before comparing results.

At 10 MHz, 5 × 10⁻¹² corresponds to 0.000050 Hz, or 50 μHz. In an ideal one-second direct count, one edge represents 1 Hz. A reciprocal counter or phase comparator can resolve less under suitable conditions, but depends on the reference, observation window and noise floor. More digits on screen do not improve those conditions by themselves.

Start with a larger verified step

Keep sample supply, termination and temperature fixed. Use an independent validated phase reference whose drift is small relative to the target difference. Record phase continuously. Begin at zero adjustment or a permitted center code, then apply a positive offset calculated using the documented control word and pull range. Verify that step before attempting the smallest increment.

Suppose an engineering check applies a known relative step of 5 × 10⁻⁹, one thousand times the listed resolution. This is 0.050 Hz at 10 MHz. Held for 10 seconds it accumulates about 0.50 cycle of phase. A 10 MHz period is 100 ns, so the phase change corresponds to about 50 ns. Fit settled phase slope and retain the switching transient separately.

A single 50 μHz step accumulated over 1,000 seconds gives 0.05 cycle, or 5 ns in the ideal case. Reference and TCXO drift, environmental changes and instrument loss of lock can be comparable over that interval. Run an equal-duration baseline and establish suitable statistics. A larger step can establish direction and scale. Verification of smaller steps requires actual measurements with adequate uncertainty.

Check whether the slope follows the code

Use equal windows at the original code, the changed code twice, then the original code again. Fit a line to phase in each window and compare slopes. This can reduce a roughly linear common drift but cannot remove arbitrary temperature compensation behaviour. Reverse the step as a separate check. Retain unwrapped phase, and repeat any window with loss of lock, a reset or missing samples.

If the project needs a correction near 0.05 Hz, apply its stated interval. A repeatable +0.049 Hz result with adequate uncertainty may support acceptance. An estimate that only restricts the change to 0 through 0.08 Hz is inconclusive. Review the reference, records and wiring, and use a larger step if necessary to verify communication separately. A successful large step alone does not certify minimum resolution.

Archive actual pull range, control words, phase reference, measurement duration and slope for original and candidate 10 MHz TCXOs. A replacement must perform the required calibration and meet the actual frequency criteria. Keep the untrimmed power-up result, especially if software can pull a unit back to nominal after an out-of-tolerance reading.

Keep a run that repeats the communication sequence without changing the selected code. A repeated write may produce a brief disturbance in the board's electrical state. If phase jumps and returns to the same slope, a single point on each side of the write cannot establish a permanent frequency change. A sustained slope change can confirm tuning even with no obvious phase jump.

Keep the specified pull range if a production issue occurs only in the original order-code configuration. Increase the engineering test step within that range before returning to the production code. If the range must change, calculate the expected response again and restore the production configuration for the final startup check. Verify that later tuning stays within the system allowance.

For a field retest, include the reference's calibration record and the intervals excluded from the phase fit.