A 125 MHz active oscillator supplies a reference to the clock tree. The converter clock looks right and the link comes up, yet the time marker for the same input pulse sometimes jumps after a power cycle. Repeatedly measuring reference frequency leaves this behavior unexplained. The AD9680 capture status and AD9528 programmable delay can reveal the SYSREF timing window on the actual board.

Identify the two edges that matter

In this example clock tree, the active oscillator provides a 125 MHz reference to an appropriate downstream stage. The device clock at the AD9680 samples SYSREF. Suppose the device clock is configured for one gigahertz. Its period is one thousand picoseconds, while the reference oscillator has an eight-nanosecond period. Substituting the latter for the capture period introduces a factor of eight. When synchronizing several chips, check the local device clock and SYSREF at each converter. Two signals generated from a common source may still arrive differently after output drivers and unequal traces.

AD9680 register 0x128 monitors SYSREF timing. Its upper nibble reports hold status and its lower nibble reports setup status. The data sheet defines the useful combinations. For example, upper nibble eight with lower nibble nine through fifteen is in a category with good setup and hold margin. Treating the whole hexadecimal value as a simple scale produces misleading results. The numeric code is neither a universal safety ranking nor a conversion to picoseconds. Read supporting state, such as the SYSREF counter, to confirm that a new event arrived before interpreting the monitor.

Fix the link rate, converter clock output, ADC divider, and SYSREF capture edge. Check electrical format, bias, and signal path against the specific devices. With appropriate probing at the pins, note which of the two paths changes delay. Deskew the channels to a common measurement plane. If adding the probes changes capture status, remove them and obtain another status reading before diagnosing the probe load. The converter's monitor gives evidence at the actual capture circuit.

Sweep delay and record the continuous passing region

AD9528 outputs have coarse and fine adjustment. Analog fine delay has a resolution of approximately thirty-one picoseconds. Enabling that path introduces insertion delay even with the code set to zero. Keep the enable state constant during a sweep to avoid mixing that step into the fine-delay sequence. If one fine range cannot reach both boundaries, shift the coarse setting and extend the sweep or use a calibrated external phase shifter. Record whether step width was measured or estimated from the nominal value.

Consider a calculation with the device clock fixed and SYSREF delay swept. At one coarse setting, fine codes four through twelve pass, while three and thirteen repeatedly report boundary problems. The endpoints of the passing samples are eight steps apart, or approximately 248 picoseconds at thirty-one picoseconds per step. Code eight is four steps or 124 picoseconds from either passing endpoint. That is 12.4 percent of a one-thousand-picosecond sample period. These settings are illustrative. The last passing sample does not locate the exact failure transition.

Suppose the budget reserves forty picoseconds for peak phase disturbance and fifty for environmental shift. Adding both conservatively calls for ninety picoseconds of one-sided margin. The nominal 124-picosecond value leaves thirty-four for fixture error, delay-step variation, and remaining temperature effects. If another converter starts passing at code seven, take the intersection for a setting shared by both devices. At code nine, the distances to codes seven and twelve are sixty-two and ninety-three picoseconds. The smaller one already falls short of ninety.

Repeat measurements at each setting using a synchronization event that reflects actual product operation. Allow the monitor to update. If continuous SYSREF was convenient for locating the window, restore the unit's intended single event or spaced events for final verification. Keep the number of valid edges and the measured link latency with each capture. One passing time marker is less informative than intermittent errors at a fixed code across several trials.

If a sweep finds two separate passing regions, check whether the delay crosses a device-clock capture edge. The codes can correspond to adjacent sampling cycles. Keep the link reset order fixed and measure the pulse latency in both regions before selecting the one that meets system alignment requirements.

Retain capture and system-level latency evidence

A replacement 125 MHz active oscillator may still give the same static frequency and lock indication while the common passing region gets narrower. Look at relative timing through the clock tree and decide whether sufficient margin remains at the final receivers. Retain delay maps for both references at multiple temperatures, including each converter's boundaries and synchronization latency distribution. A window that moves when changing an output path suggests a branch issue. If several converters move together after the reference changes, check the source and downstream clock configuration and transients.

For handoff, record sample rate, capture edge, valid codes, the code chosen for each converter, and the smallest measured one-sided margin. The register indicates local capture conditions. Time markers across power and reset cycles show the system outcome. Use both to accept synchronization in the assembled system.