A 125 MHz oscillator clocks the faster AD9648 version. Two small discrete lines appear beside the clock carrier. When the analog input frequency changes, lines in the ADC record move with the signal and may reverse sides. Clock accuracy alone cannot explain this. Inject a known small timing deviation on an engineering bench and compare the sampled sidebands with the prediction.
Hold the clock, analog source and acquisition settings constant
The faster AD9648 supports 125 MSPS. Its datasheet specifies clock conditions, analog drive and aperture uncertainty. Fix divider mode and sample rate, and verify termination and swing at the ADC so changing sources does not change edge amplitude. For diagnosis use a validated clock source with controllable phase modulation in place of the oscillator on a working engineering board.
Capture a baseline without modulation. Record analog tone frequency, amplitude and filtering. Choose enough data to resolve the sidebands and apply the same window and analysis rules. In a coherent setup, ensure a common reference does not carry the injected modulation to the analog generator. With independent sources, handle leakage from the FFT window so a skirt is not reported as a spur.
Measure actual clock phase or edge displacement at the receiver and record the injection settings. Symmetric sidebands alone do not establish phase modulation. Analog Devices AN-1386 explains that small-signal AM and PM spectra can look alike and analyzes the effect of clock noise on ADC output. If modulation changes amplitude as well, measure that contribution before applying a timing-only estimate.
Use the actual analog input frequency to calculate sideband level
Suppose the 125 MHz clock has sinusoidal edge motion at 120 kHz and 1.0 ps peak. For a 30 MHz analog input and small timing error, peak sampled phase deviation is about two pi times the analog frequency and peak time displacement, or 0.000188 rad. Each sideband has roughly half that amplitude relative to the tone, about −80.5 dBc, at 29.880 and 30.120 MHz.
Now move the analog input to 90 MHz and keep the measured time deviation and processing unchanged. The input changes faster at the sample instant. Peak phase deviation is about 0.000565 rad and the estimated level is −71.0 dBc per side. The threefold analog frequency raises the relative sidebands by about 9.5 dB. This assumes a single tone and small deterministic phase modulation. Generator spurs or converter nonlinearity can also contribute.
At 125 MSPS, real sampling folds a 90 MHz input to 35 MHz. The original 89.880 MHz side becomes 35.120 MHz, and 90.120 MHz becomes 34.880 MHz. The offset remains 120 kHz while the upper and lower labels swap. The amplitude estimate still uses 90 MHz. Substituting the displayed 35 MHz would underestimate sensitivity to sampling time.
Use three controls before replacing the oscillator
First, hold the analog tone fixed while toggling the controlled clock modulation. Check whether both lines appear and disappear. Second, use two input frequencies and compare the positions and relative levels with the timing prediction. Third, put the original 125 MHz oscillator back with its normal supply and termination. If the lines recur, compare the oscillator's phase measurement and ADC spectra using original and candidate devices. If changing the oscillator removes the clock spur while the ADC lines remain, investigate the analog source, coupling or digital processing.
An appropriate analog filter can help prevent unrelated RF from entering when the source frequency changes. Use a consistent relative amplitude reference such as dBc to each fundamental. Different digital gain or input amplitude can make absolute plots misleading. Verify that ADC codes do not clip or contain digital capture errors before comparing sidebands.
For a project limit of −75 dBc at the specified offsets, the 30 MHz illustration passes and the 90 MHz one fails. Save the sample rate, true analog frequency, folded locations, measured phase displacement and window. A part's integrated jitter specification cannot by itself establish this system-level discrete spur result.
Estimate resolution in advance. With 125,000 continuous samples at the example rate, the record is 1 ms long and the bin spacing is 1 kHz. A 120 kHz sideband sits 120 bins from the tone. Whether a line near −80 dBc is measurable still depends on the noise floor, window sidelobes and modulation stability. Bin spacing alone does not establish sensitivity.
If the sides become markedly unequal after changing the tone, retain the complex spectrum or observe clock amplitude and phase independently. Multiple noise sources at one modulation frequency can add or cancel. Repeat at another controlled offset away from known supply frequencies. Pair motion with the new offset helps distinguish the intended timing path from unrelated lines at the original frequency.
Before comparing another lot, rerun the baseline without modulation to check that reconnecting the analog source did not add a line in the band of interest.