Two LMK61E2 configurations produce 125 MHz. Why measure phase jitter on both?

Configured as a 125 MHz programmable differential oscillator, TI's LMK61E2 reaches that frequency with different internal multiplication and output-division settings. The counter may show the same frequency for both. Equal frequency does not establish equal PLL conditions. Before substituting a device or programming image, associate integer or fractional mode, internal oscillator frequency and loop settings with the measured phase noise and spurs.

Two settings can reach the same frequency by different paths

The LMK61E2 datasheet gives the relationship. An internal 50 MHz reference may be doubled, then multiplied by the feedback ratio to obtain the VCO frequency. The output is an integer division of the VCO. Its VCO range is 4.6 to 5.6 GHz. Read back the reference doubler, feedback integer and fraction, output divider and status. A 125 MHz reading only establishes their combined result.

For two illustrative ratios, enable the doubler in both cases, giving a 100 MHz phase detector reference. Output divide by 40 requires a 5.000 GHz VCO, so the feedback ratio is the integer 50. Divide by 41 requires 5.125 GHz, with a feedback ratio of 51 plus one quarter. Both calculations give 125 MHz and keep the VCO within the documented range. A working image also requires the specified modulator, loop filter and calibration settings. The ratio is only one step.

The example changes internal VCO frequency and output division as well. If spectra differ, the measurement initially compares two complete configurations. It cannot attribute the full difference to fractional division. For diagnosis compare more than one verified configuration while keeping supply, temperature, reference doubler and output format fixed.

Compare phase noise and spurs through the same interface

Keep the same output format and load on the LMK61E2, such as matching both tests to the recommended LVDS configuration. Use a differential measurement input or a validated balun and measurement chain. Keep cable and receiver drive conditions fixed. Refer to the EVM documentation for connections. Verify the chain's bandwidth and noise floor before attributing a low result to the oscillator.

Follow the device's programming and VCO calibration sequence on both runs. Record status and key settings, then measure after settling. Save status readback promptly because some documented events clear on read. Test configuration A, then B, then A again. A repeatable change following configuration supports the comparison. If A no longer repeats, inspect instrument floor, temperature, rail and termination.

The datasheet provides separate phase-jitter limits for integer and fractional modes under specified conditions. Use the same integration band and record how discrete spurs are treated. If one setting introduces a narrow line, verify its offset and amplitude with suitable resolution. Check with a clean supply or known reference source to determine if the bench produces the line. Save the supply configuration with the spectra.

Link operating limits to the final programming image

Suppose the project allocates 220 fs RMS to the oscillator in a defined band. Under otherwise equal methods, A measures 160 fs RMS and B measures 240 fs RMS. A meets that limit and B does not, even though both are 125 MHz. With an 8 ns clock period the values correspond to roughly 0.000020 and 0.000030 unit intervals RMS. They are neither peak error nor lost clocks. If the project specifies a discrete spur at a particular offset, check it independently.

Save the actual production image for this 125 MHz programmable differential oscillator. Verify whether power-up restores an EEPROM image or the host writes its configuration. Production test must be able to recover the readback state and spectrum. Purchasing needs the output format and measurement conditions alongside frequency. Rerun the production startup path after changing the configuration.

If the two configurations give somewhat different output amplitudes, verify amplitude sensitivity and ensure both are inside the measurement chain's input range. Check the noise floor through a reference path without changing the DUT termination. Repeat on the final board before referring a mode-dependent difference for design or supplier investigation.

Use equivalent observation time when comparing discrete lines and broadband noise. If one analysis omits lines near its lower integration boundary while another includes them, the different outcomes can reflect processing alone. Keep separate results for each specified band and preferably measure both suppliers under the project's band and spur rules. Apply the product's convention to lines near a boundary.

If charge pump or loop settings differ, retain more than the integer or fractional label. Read back the reference doubler, feedback ratio, output divider and applicable loop settings. A later firmware change can then be compared against the original values on the same board. With only nominal frequency preserved, a changed spectrum cannot readily be traced to a setting.