A scope shows continuous clock at the output of a 125 MHz LVDS active oscillator, but the receiver logic settles later. With blocking capacitors in both conductors, the differential trace can hide a second transient. The receiver establishes its own DC bias. There may be enough differential swing while the mean voltage of both pins remains outside the allowed range.
Record both single-ended voltages
TI's LMK00306 data sheet discusses establishing driver and receiver DC bias for AC-coupled LVDS, as well as startup delay from capacitor charging. Receivers with internal termination, internal bias, or external bias can use different arrangements. Draw the DC paths for the actual source and receiver to identify who establishes common mode on each side.
Capture both lines near the input with suitable loading and range. Their difference is differential voltage, and their average is common mode. Verify channel skew and offset first. Imperfect addition can create apparent spikes during fast transitions. A differential probe alone usually shows swing and crossings without showing the common-mode voltage. Also capture receiver power, enable, and digital output to locate where the delay starts.
Why the across-pair resistor does not set common-mode charging
When both inputs move together, the voltage across a 100-ohm differential resistor changes little. Bias recovery depends on the effective paths from each line to its bias, ground, and source. Suppose a symmetric example has 10 nF coupling on each line and 5 kilohms effective resistance per leg, with other resistances negligible. The common-mode time constant is about 50 microseconds. Using the differential termination instead would give a time constant for a different model.
Assume a starting common mode of 0.70 V, final bias 1.20 V, and an illustrative valid threshold of 1.10 V. At that threshold 0.10 V remains, one fifth of the original difference. A first-order response takes 50 microseconds times the natural logarithm of five, or about 80.5 microseconds. At 125 MHz that spans roughly ten thousand nominal cycles. This is a duration, not a count of measured missing pulses or a guarantee for a receiver.
Compare a cold start with output re-enable
After full power removal and the required off time, capture the source, both sides of the capacitors, receiver power, and control markers. Then re-enable the oscillator with receiver bias maintained if supported. A longer initial delay than re-enable may arise from capacitor charge or receiver supply history. If the oscillator output itself appears late in both cases, inspect its startup before attributing delay to receiver bias.
Match initial charge or document it. A short interruption may retain bias while a long one discharges the path. Mismatched coupling parts can temporarily convert common-mode movement to differential voltage, so the result need not be a simple exponential. Retain both waveforms and distinguish when common mode enters range from when differential swing meets requirements. Record the downstream status or count where available.
Keep startup evidence for the replacement
Compare 125 MHz LVDS oscillators using separate measurements for source clock, receiver common mode, differential swing, and first accepted edge. A faster source may not help when receiver bias dominates. A different disable or startup output state can change initial capacitor voltage and recovery on the same board. Fixed loading and bias controls distinguish these effects.
If changing coupling capacitance, verify the allowed circuit and retest swing, lowest operating frequency, and maximum interval without edges. Continuous-clock testing cannot establish sleep recovery or burst operation. Document capacitance and actual bias, then check the product's valid-clock deadline and electrical limits.
Check whether the waveform follows the first-order model. Sample common mode at several points near entry and compare how its distance from the final value shrinks. A plateau, step, or reversal can reflect staged bias enable or temporary clamp conduction. Retain the final value and power state during the anomaly. Charging alone will not describe those conditions.
A practical control keeps the oscillator and capacitors fixed while establishing receiver bias earlier using a supported sequence. If valid common mode and the first accepted edges then move together, bias settling is supported. If the receiver output remains equally late, check reset, failsafe, and downstream initialization. Use a shared power or enable marker for both records.
Specify whether the limit is first entry or sustained operation and verify differential amplitude several cycles later. A single early crossing does not establish sustained reception.