A dual-channel acquisition board uses a 125 MHz LVDS oscillator for an ADS42LB69 configured for QDR output. The receiving FPGA locks to the bit clock and sees the test pattern. After some restarts, captured values look consistently rearranged even with no corresponding change at the analog input. Verify which of the four serial slots starts each group before adjusting receiver delay. The bit clock establishes the sampling opportunities. The frame clock helps identify which bits belong to each converter sample.
Identify reference, bit clock and frame clock on the schematic
The manufacturer's QDR diagram places four serial bits on each of four differential data pairs per channel. Each channel has its own bit clock and frame clock. Figure 86 shows the ADS42LB69 bit order, while the neighboring ADS42LB49 diagram has another assignment. In the FPGA interface record, list the physical pair, the slot position on that pair and the corresponding position in the 16-bit sample. Physical pair names alone do not describe time-slot order.
In this example a 125 MHz LVDS oscillator reaches the ADC through a suitable input network, and the clock is undivided. The converter therefore produces 125 million samples per second, with 8 ns per sample. Each pair carries four bits in that time, or 500 Mbit/s and 2 ns per bit. Receiving on both edges corresponds to a nominal 250 MHz bit clock. That frequency establishes a rate. A receiver that groups bits one slot late can repeatedly assign them to the wrong positions at the same rate.
Check the conditions on both sides of the clock connection. TI lists the LVDS input in an AC-coupled configuration. Verify amplitude and the applicable circuit. Identify whether the board uses the installed oscillator or a lab source, and inspect the ADC divider. If the sampling rate differs, recalculate the serial rate from the actual sampling rate. Keep the sampling input, forwarded bit clock and any later recovered clock under distinct test point names.
Use different evidence for stable errors and random errors
Start with the manufacturer's digital test mode to remove analog input variation. All zeros or another uniform pattern can show unexpected bit flips, but rotating its slots may leave the word unchanged. Use words that distinguish positions, then verify with a changing pattern. For example, suppose a lane should carry one, zero, zero, zero over four named slots. A repeatable zero, one, zero, zero calls for checking frame interpretation, receiver phase and physical mapping. This is a sample slot pattern. Derive actual custom register values from Figure 86.
Random intermittent errors call for looking at the sampling eye and interconnect. Hold frame interpretation fixed, compare errors at different sampling positions, and observe the bit clock and data. If the same predictable wrong word appears across a broad timing interval, verify word assembly before tuning delay. Test both channels separately to see which alignment changes after restart.
Accept the first valid block after a restart
Record ADC reset and programming, test-pattern output, receiver alignment and when data is marked valid. Apply the manufacturer's power-up reset sequence, then repeat with a receiver-only reinitialization. Save the frame reference and slot map. When returning to normal conversion, use an identifiable input to prove sample order and channel assignment. Check whether a first buffer delivered before alignment is correctly marked invalid.
Use a pattern long enough to expose grouping across sample boundaries. Capture two distinguishable words, retain raw serial order and reassemble from the frame reference offline. If this differs from the FPGA output, compare the first slot where they diverge. An intentional one-slot offset can provide a reference failure trace for later comparison. If a new failure looks different, continue checking pair order and polarity.
Record how many starts reached alignment and whether the first block declared valid passed the word-order check. When initialization reloads sampling delays, verify that the receiver domain is running before completing calibration. Systems that correlate channels should also check that the first valid sample on each corresponds to the intended conversion event. Test local word boundary, timing margin and channel association separately.
For a 125 MHz LVDS oscillator sample or board clock change, record source selection, the ADC divider, data-pair mapping and comparisons after repeated cold starts and receiver resets. Save input clock and forwarded clock traces alongside constant and changing test-pattern results. A repeated wrong word can then be compared with a known one-slot shift before retuning the sampling window. In this use case the receiver must reconstruct the same samples after multiple starts.