Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / System Validation and Replacement

Why can a DS90LV001 produce more edges after its 125 MHz LVDS source is disabled?

A 125 MHz LVDS oscillator feeds an acquisition card through a DS90LV001. During normal operation, both sides show stable 8 ns periods. When the source is disabled, the acquisition counter occasionally advances again. Check the source's actual disabled output state and whether the buffer remains enabled. If the source releases the pair, the termination no longer sees its normal driven voltage. Small disturbances can cross the receiver threshold and show up as edges on an enabled output.

Locate whether the edges originate before or after the buffer

The DS90LV001 data sheet specifies no internal failsafe input bias and a separate enable that can place the output in high impedance. Check those cases separately. With the buffer output enabled, stop or tristate the source and capture the buffer input, output and downstream count. If the input is no longer a normal clock but the output toggles, inspect bias on the undriven receiver and nearby coupling. Then tristate the buffer itself. If the downstream receiver still counts edges, inspect its own termination and idle behavior. Disconnecting the buffer's output drive leaves another undriven pair to consider.

Oscillator models can differ in what output disable does. Some tristate, while a fixed output polarity is possible on other parts. Check the exact ordering code and pin definition. Removing an upstream card produces another source-loss condition. The remaining termination and bias can differ from normal oscillator disable. Exercise software disable, oscillator power loss and physical removal separately while downstream power remains stable. A single frequency reading cannot distinguish these states.

Calculate the differential offset of the external bias

TI shows 20 kΩ from the positive input to 3.3 V and 12 kΩ from the negative input to ground. Assume a 100 Ω differential termination, a source completely in high impedance and no leakage or additional branches. The three resistors form a DC path drawing approximately 102.8 µA. The voltage across the termination is about +10.3 mV and the input common-mode voltage is about 1.24 V. These estimates are useful for finding assembly errors. If the measured magnitude differs greatly, check termination, extra bias or a source that did not actually release the pair.

The specified upper bound on the high differential threshold is +100 mV. The resistor example biases the idle pair positive. Its calculated 10.3 mV does not establish a guaranteed noise margin across production. TI's dedicated bias note distinguishes typical switching threshold from noise margin. If an edge counter must see no edges while the source is absent, verify that under the project's power, temperature and interference conditions. Use a receiving stage with a specified idle behavior or a system-level qualification strategy when the requirement calls for it. Check where counting stops when valid input disappears.

The pull-up and pull-down also affect the driven pair. Before using smaller resistors for a stronger idle bias, include their load and check the negative swing and common-mode voltage with the oscillator active. A second termination, an existing module bias network or a change from DC to AC coupling invalidates the simple series calculation. Record which optional components are actually fitted. Use the same assembly and the longest cable to check the active 125 MHz LVDS waveform and source-off behavior.

Termination affects the result in another way. Two 100 Ω resistors across the same pair present about 50 Ω in parallel at DC. With the same pull-up and pull-down and no other paths, the idle differential falls to about 5.15 mV. If the idle trace has only a few millivolts, check for that parallel load before changing the bias. On other assemblies, disconnecting the source may also remove one termination, changing the equivalent circuit in the opposite direction. Record termination position and effective resistance for each connection state and make sure that the termination still suits the active waveform. Capture supply disturbances at turn-off as well, since movement of downstream reference levels can create false counts.

Record valid pulses and false idle edges separately

Trigger on source enable and record buffer enable, differential input, differential output and the downstream counting window. A probe can change the idle voltage, particularly when the differential bias is small. Verify the probe loading and measurement bandwidth. Measure the stable DC polarity first, then capture short transitions on disable and restart with a differential probe. Include a steady idle interval with neighboring digital circuits operating so intermittent coupling can appear.

For handoff, save active swing and common mode with the fitted 125 MHz LVDS oscillator, idle voltage and counts with the source in high impedance, and the first valid period after restart. If counting is used to declare that a connection exists, note when counting becomes valid again. The same record should let another engineer reproduce both the active waveform and the absence of false idle edges.

References

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.