Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Measurement and Acceptance

Why does the receiver produce one more edge after the 125 MHz LVDS oscillator is disabled?

A board disables a 125 MHz LVDS oscillator. The receiver usually settles high, but sometimes produces one more rising edge. Capture differential input, receiver output, oscillator enable, and the downstream count together. Some receivers actively drive high when they no longer detect a differential signal. A downstream counter can register that transition. A substitution test should establish both when the source stops and how the chain settles.

The receiver can set its own idle level

The TI SN65LVDS33 data sheet distinguishes the high-speed receiver from its delayed failsafe. A window comparator monitors differential amplitude, with about 80 mV shown in the circuit explanation, followed by a timer. When the condition qualifies, failsafe drives the output high. A disconnected line, disabled transmitter, and terminated line with reduced swing are distinct electrical conditions. A static output high does not show that the last input bit remained high.

The circuit description mentions 600 ns. The switching table separately lists an activation delay from 0.3 to 1.5 microseconds under its specified load and test waveform. The 125 MHz period is eight nanoseconds. One and a half microseconds corresponds to about 188 nominal periods. This tells the test team how long the observation window may need to be. It does not represent clock pulses actually present after disable.

Whether a rising edge appears also depends on the preceding output state. When the main receiver stops low, failsafe taking over can create a low-to-high transition. If it is already high, the last visible edge may precede shutoff. Starting from different phases can change the count by one. Handle any noise crossings before failsafe separately from the timed transition.

Capture input and output on separate channels

Check whether the exact receiver includes termination and record the real termination network. Probe differentially near its inputs. If common mode is suspect, measure the line average using an appropriate setup. Capture the single-ended receiver output separately. Trigger on an independent enable or system marker. Retain normal operation, reduced amplitude, failsafe takeover, and resumption.

Disable the oscillator using a documented method and respect electrical ratings. One 125 MHz LVDS active oscillator may enter high impedance, while another has a specified driven idle state. Check the definitions of standby and output disable. A controlled differential source can qualify the receiver by moving from a valid signal to a specified low differential input within common-mode and termination limits.

Send disable at several phases to make controls with the previous output in both states. If differential input remains healthy while output stops, examine enable, receiver power, and downstream logic. If differential edges disappear and the receiver later rises once, compare the timing with the documented conditions and a controlled source. On return, record when failsafe releases. Activation and deactivation are different specifications.

Set acceptance according to what downstream logic counts

If no pulse may be counted after shutdown, a receiver's final high state alone gives insufficient evidence. Use an independent marker to show when downstream masking takes effect relative to the last effective transition. If a system only needs a stable idle output, specify settling time separately. The same capture can support both decisions.

For each 125 MHz LVDS active oscillator, retain disable request, differential input, receiver output, final accepted edge, and the first valid edge on restart. Span the failsafe delay and repeat at applicable temperatures and power sequences. If the substitution changes only the source's disabled output state, record the resulting board-compatibility behavior so it can be retested for the next lot.

If slow capture shows only the final state, use a fast acquisition that resolves the pulse width. A short fast record can miss the full failsafe delay, so locate the interval with a longer capture and verify edge details from timestamped acquisitions. Repeat both with a controlled event and compare against the system's edge log.

Verify receiver power throughout the stop event. If the product removes power from the receiver as well, an external pull-up can make a high-impedance output rise slowly. Check rail, enable, and load. Run a control with receiver power maintained, then repeat the normal product shutdown sequence and retain both captures.

References

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.