A rack clock card starts first and delivers its 125 MHz LVDS oscillator to an LMK1D1204 on a main board. The buffer supply rises later, and the controller leaves the select pin high impedance while in reset. The input scope trace shows a continuous clock, but the outputs are initially static. TI specifies that the buffer can tolerate an input before its supply under stated conditions. That does not enable fanout. Capture the buffer rail, select state, output and downstream reset to determine which event controls startup.
Fail-safe input addresses supply sequencing
The LMK1D1204 data sheet describes fail-safe operation that permits driving the input before VDD is applied, subject to the specified input conditions. Check other devices on the net separately, including external clamps and switching components. A shared differential pair does not give each attached component the same tolerance. Across boards, verify the ground reference and each physical pin's permitted range. Passing repeated startup tests cannot extend a component's documented electrical limits.
TI also describes input hysteresis intended to prevent random oscillation when there is no signal. That is a receiver characteristic. An open conductor, out-of-range common mode or a disturbed input is a separate failure condition. If the downstream system relies on a defined clock-off state, use a documented control condition and observe the actual receiver rather than inferring a safe condition from a disconnected input.
Open IN_SEL is a distinct operating mode
The input selection table maps low and high to the two inputs. Leaving IN_SEL open disables the input buffers and sets static logic low at the outputs. A controller in reset therefore does not necessarily select input zero when its GPIO is high impedance. Establish when the select pin is driven to a valid level before assigning a missing clock to the 125 MHz LVDS oscillator. The logic-low description is for the differential state; it does not imply that both physical pins are at ground.
One 125 MHz period is 8 ns. Suppose the buffer has valid power but IN_SEL remains open for another 32 microseconds. Roughly 4000 nominal input cycles can pass during that illustrative window while the output is in the disabled state. The count is an example, not a specified buffer startup sequence. Measure how long the actual output takes to become valid once selection changes. Do not assume the first transition after selection necessarily provides a fully qualified clock interval.
Verify cold starts and controlled restoration on the loaded board
Capture the differential input at the buffer, its supply, and the actual select drive in a known assembly. Retain the GPIO's high-impedance reset interval and the first valid output edges after selection. If a receiver uses the clock for synchronous reset release or data capture, record the moment it begins relying on those edges. The ability to tolerate an early input and ability to run the complete system are separate parts of acceptance.
For a controlled comparison, keep the 125 MHz LVDS source and buffer power valid and change only the select state, within the board's supported controls. Verify how disabled and active states appear at the downstream receiver. If both inputs have the same frequency, a counter cannot identify the source. On the bench, differentiate the sources using valid identifiable inputs or isolate one path at a time. After replacing the surface-mount oscillator, repeat the control tests with the same termination and power conditions. The record should identify the selected input, output waveform, and downstream start.
If the software reads a clock-status register, record when it does so. A later flag does not establish readiness for a particular earlier edge. A failure that occurs only when the select controller resets again is a reason to capture the high-impedance interval on that path.
A repair fixture can change the circuit being tested. If the controller normally drives IN_SEL directly, a fixture may inadvertently add a pull-up or pull-down, selecting a clock before the controller would. Check the actual open-state conditions and any installed resistor networks with the external driver removed. Capture static and selected operation at similar time scales and at the same downstream point. This makes it easier to compare the buffer mode against the receiver's response.