Why should four cards not each add 100 Ω to a backplane driven by a 125 MHz LVDS oscillator?

One 125 MHz LVDS oscillator clocks a single acquisition card. A later revision adds four slots with branches from the same pair and copies the original 100 Ω receiver termination onto each card. One card works, but the full rack occasionally loses acquisition samples. Point-to-point and multipoint clocks use different topologies. Choose individual fanout routes or a purpose-built multipoint bus before deciding how to terminate the loads and handle removable cards.

Decide whether the clock travels on four pairs or one

When routing allows, a low-skew fanout buffer can drive four independent pairs. Terminate each link for its own source and receiver. Removing one card does not directly change the other three receiver loads, although the unused output state still needs checking. In this setup the 125 MHz LVDS oscillator just needs to match the buffer input. Simultaneous sampling still requires a skew budget for buffer outputs, traces and receivers. Equal frequencies do not establish aligned arrival.

A single shared pair calls for a multipoint driver and receivers. TI specifies the SN65MLVD040 for signaling rates up to 250 Mb/s and clocks up to 125 MHz. It handles stated differential loads from 30 Ω to 55 Ω and has controlled transition times for multipoint stubs. Its logic inputs are LVTTL. An LVDS oscillator needs a suitable LVDS receiving stage first with enough remaining pulse width, or use a suitable single-ended clock for the logic input. The moving differential pair is not one logic input. Specify which segment is LVDS and which is M-LVDS.

Terminate the bus ends rather than every slot

Assume a 100 Ω differential main route terminated with 100 Ω at both physical ends. A low-frequency load estimate is 50 Ω. If four cards add another 100 Ω each, all six paths in parallel give about 16.7 Ω, below the cited example's load range. In a real high-frequency bus these points are distributed along the trace. The static estimate identifies an obviously unsuitable population without claiming a waveform prediction. Include removable termination cards or other fixtures in the same drawing. If removing the last card opens the termination, provide an intended termination scheme for legal reduced populations.

Each slot connection also adds a stub. With an assumed propagation velocity of 160 mm/ns, a 30 mm stub has a round-trip delay of about 0.375 ns. That can be sizable next to a nominal 1 ns class edge. Use the actual stackup and geometry before assigning a limit. Simulate or measure the longest and shortest branches and exercise the capacitive loading of populated cards and the open stubs of empty slots.

Exercise permitted populations and receiver states

Draw physical ends, current driver and card power states. Observe source, nearest receiver and farthest receiver. Keep differential amplitude, common mode, high and low widths and acquisition errors under the permitted populations. For Type-1 or Type-2 receiver operation, use the specified thresholds and check output with no active driver. An offset failsafe threshold can move the crossing point. Record it when comparing card arrival times.

With alternate clock cards, verify who controls driver enable. Two outputs can contend even if both oscillators are nominally 125 MHz. Test initial startup and authorized transfer of the source, and save the first clock sequence after handover. Keep receivers in the intended state while clock is absent. Once it returns, qualify duty and system lock. A later successful lock does not account for an extra short pulse at handover.

Retain actual termination values, stub geometry, card population and driver suffix. Near the rated maximum, account for oscillator tolerance and verify available headroom with the manufacturer. The oscillator specification supplies the 125 MHz source conditions. Backplane acceptance needs fully and partially populated configurations, power-off slots and recovery. A single-card result cannot validate all of them.

Exercise card combinations even after the fully populated rack passes. A lone far-end card can show more ringing if additional loading happens to damp a reflection. Record measured levels and edges by physical slot and identify the absent cards. Where live insertion is supported, check whether existing receivers lose a cycle. If data is intentionally blanked during insertion, verify the interval marked invalid. A mechanically fixed end card also belongs in the set of valid topologies.

References

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.