An older module uses a 125 MHz LVDS oscillator. Its replacement FPGA accepts a single-ended clock at the chosen pin, so the new board uses a differential receiver. The LVDS input is near 50% duty, but only one polarity of the single-ended pulse has plenty of time. Ask two questions about the translation. How far did the entire waveform move, and how differently did rising and falling edges move? Equal delays can preserve both widths. Unequal delays can change the widths even while the counter still reads 125 MHz.
Budget the shorter pulse
TI lists low-to-high delay, high-to-low delay and pulse skew separately in the SN65LVDS2 data sheet. Pulse skew is the absolute difference between the two delays. Under the receiver's documented switching conditions with 10 pF output load, its maximum is 0.6 ns. Absolute delay belongs in the arrival-time budget. Pulse width depends on edge-delay difference. Subtracting an entire propagation delay from a half-period would treat a uniform shift as lost pulse width.
At 125 MHz, one period is 8 ns. Suppose the incoming high and low are each 4 ns. A falling edge delayed 0.6 ns more than its rising edge produces about 4.6 ns high and 3.4 ns low. The other sign can make the high shorter. If the oscillator itself allows 45% to 55% duty cycle, its shortest half can already be 3.6 ns. Deducting 0.6 ns conservatively gives 3.0 ns, or 37.5% of a period. A receiver requiring each polarity to last at least 3.2 ns has a 0.2 ns budget shortfall. A room-temperature sample at 48% does not cover the stated limits or a higher future load.
Follow the differential crossing to the logic threshold
Observe Vp−Vn at the differential receiver and keep the data-sheet test conditions with the measurement. Equal line voltages mark a differential zero crossing. The receiver has a threshold, load, and permissible common mode. Input offset, phase imbalance, and edge slew can move the actual switching instant. For single-ended output, measure with the appropriate receiver thresholds. A frequency estimate between like edges cannot reveal displacement of the opposite edge. Record both threshold definitions and probe loading.
Distinguish the SN65LVDS2 from the integrated-termination SN65LVDT2 and check a candidate's exact suffix. Match external stuffing to the device. A before-and-after trace cannot establish cause if termination and output loading changed together. Hold the oscillator and route fixed while comparing input amplitude, common mode and widths. Then hold that input fixed and measure the single-ended output. Change output loading in one test and differential conditions in another to isolate input crossing error from distortion on the logic path.
Verify the shortest pulses and reset release
Record minimum high and low separately. For a failing pulse, preserve preceding edges, differential input and the local supply. A long average hides isolated short pulses. Test with actual FPGA loading at supply and temperature limits. If approved FPGA options have different specified minimum widths, qualify each at its selected clock pin.
The oscillator record should specify duty window, test method and load. Retain the receiver suffix, supply, load and total width budget with the board. If clock can stop during startup, test the first valid pulse sequence before releasing the consumer from reset. A steady-state duty statistic does not establish that transient. The result should show how much time each polarity leaves at the actual receiver.
If the source begins after a configuration command, mark oscillator enable, receiver power and FPGA reset on the same timeline. Distinguish a narrow pulse after translation settles from a consumer that starts counting before its input is valid. For a design that uses both edges independently, exercise and count both classes of operation so a passing rising-edge path cannot hide failures on the falling edge.
If the sign of skew reverses with temperature, retain the joint high and low pulse distribution for each board, supply and temperature. Apply each minimum to its own path if the system uses the two edges differently. When testing another oscillator lot, keep probe location and threshold fixed and check the worst combination of source and translation. A favorable half-cycle from a different capture is not evidence of margin.
Repeat with the actual production test head and with a characterized probe arrangement. If the short pulse appears only with the fixture attached, investigate its capacitance and wiring before assigning the fault to the product. Keep both waveforms and the threshold used to extract them. A replacement receiver needs both edge delays reviewed again, not just its typical propagation delay.