After harness repair, a board occasionally reports loss of clock. A scope on P relative to ground still shows 125 MHz. If the N conductor is open, P can remain active and parasitic capacitance can transfer part of the signal into the broken leg. A single-ended frequency reading can miss the open. Qualify the 125 MHz LVDS oscillator link with separate single-leg and two-leg opens, then observe the actual receiver.
Test single-leg opens separately from unplugging the harness
Record the normal source and receiver waveforms first. Use an engineering adapter with the original connector arrangement and a well-defined place to open each leg. Compare all four states: both connected, P open, N open and both open. Keep receiver termination, bias and power. An adapter, switch or jumper adds trace length, so compare its intact state with a direct connection. Follow the approved power sequence when changing states. For a static test it may be sufficient to configure each open with power removed and then restart.
The TI DS90LV012A family datasheet distinguishes open inputs, removal of the driver with end termination in place, and a short across the inputs. Fail-safe behaviour depends on the listed connection and common-mode range. With only one conductor open, the other remains driven and termination still bridges the inputs. Behaviour after unplugging both conductors cannot establish behaviour in that condition. A fixed output on one board should be verified against the exact receiver and over required voltage and temperature.
Capture P and N against the same local ground and compute both P minus N and the common-mode average. Deskew the channels and use symmetrical pickup points. A differential probe can show the differential waveform without revealing its common-mode shift. Record receiver output or an independent clock-loss latch at the same time. Even if the system switches to a backup clock, the recording can reveal unexpected input events before the transfer.
Calculate the voltage at both settled states
Suppose a correctly terminated 125 MHz LVDS oscillator gives P = 1.39 V and N = 1.03 V at the receiver. The differential value is +0.36 V and common mode is 1.21 V. Reversing the leg voltages gives −0.36 V and the same common mode. The differential waveform is 0.72 V peak to peak. Label the convention before comparing two reports that may quote different amplitude definitions.
For a hypothetical N-leg open, suppose P and N are 1.37 and 1.29 V in one state. The differential input is +80 mV and common mode is 1.33 V. In the other state they are 1.04 and 1.12 V, giving −80 mV and 1.08 V common mode. The DS90LV012A permits a worst-case low threshold of −100 mV under its specified conditions. Some devices may switch at −80 mV while a guaranteed low cannot be inferred. These example voltages illustrate the comparison. Measure the real fault waveform rather than scaling the normal swing by an assumed ratio.
The nominal period is 8 ns. If the receiver switches briefly at particular phases, a frequency display may still settle near 125 MHz. Check edge spacing, minimum widths and loss-of-clock events. Capacitive pickup on an open leg may produce a narrow spike. A maximum-minus-minimum measurement over the entire sweep cannot establish both logic states or their time at valid levels.
Use the injected fault to focus physical inspection
Record intact and failed states with the same source drive and termination. If the operational fault matches the N-open setup, power down and check that conductor along each segment. Isolate indirect paths through protection and nearby circuitry before using a continuity reading. Move a flexible harness only within its permitted range and check again. Some connections pass DC and fail at high frequency, in which case a passive reflectometry check can help locate the fault. Preserve an intermittent connector in its failed position when possible.
The fault may also alter the oscillator's load. Compare its source waveform in the fault fixture with a suitable receiver that gives the specified intact termination. Adding another 100 Ω at the source while the original receiver remains connected changes the load and may hide the relevant result.
Keep traces and receiver status for all four connection states, along with recovery behaviour. If a broken line must be flagged within a defined time, use an independent timebase to measure from the last valid edge to the fault report. Verify output pulse quality and recovery delay after reconnecting. Acceptance then covers both normal clock generation and the product's defined response to a connection fault.
To distinguish a broken leg from external pickup, open both legs while keeping nearby supplies, clocks and shielding unchanged. Check whether a periodic signal still appears at the receiver. A board can have several clocks at the same frequency. On an engineering board, a permitted alternate test frequency or an independent activity marker can distinguish pickup from the original connection.
If production checks the loss-of-clock alarm, validate that diagnostic with intentional opens on a known-good sample. The real harness requires its own wiring and continuity checks, including before and after approved movement or vibration where applicable. Show termination and fixture port locations in a drawing. Note whether partial connector removal can break one contact first. The same fault case can then be repeated on boards with an alternate oscillator.