A datasheet lists several hundred millivolts of differential output, but a scope shows a peak-to-peak value near 760 mV. Before treating the driver as excessive, identify the two settled states. Datasheet VOD often means differential magnitude in a particular state. A peak-to-peak trace spans both positive and negative plateaus. Compare under the same termination and definition. A plausible overall swing can still conceal imbalance.
Calculate differential and common-mode values for each state
Take differential voltage as positive output minus negative output and common mode as their average. In an illustrative first state, the outputs are 1.45 and 1.03 V. This gives +420 mV differential and 1.24 V common mode. In the second state they are 1.11 and 1.45 V, giving −340 mV and 1.28 V. The difference between the two differential plateaus is 760 mV. The two VOD magnitudes are 420 and 340 mV, with 80 mV mismatch. The common-mode states differ by 40 mV. Transient overshoot is excluded from these plateau values.
Epson's brief for the SG3225VEN family and related parts lists 250 to 450 mV for LVDS VOD and a 50 mV limit for the difference between the two VOD magnitudes. It also specifies output offset and its variation. The example's individual magnitudes lie inside that VOD range, while their 80 mV difference exceeds the stated 50 mV limit. Comparing 760 mV directly with 450 mV, or reporting only half the full swing as 380 mV, misses this distinction. Use the exact part's conditions. When a table specifies a DC method, waveform plateaus can guide diagnosis, with formal measurement under the specified mode and load.
Preserve the intended cross-line termination
Check whether the board already contains its termination. The referenced LVDS example calls for 100 Ω across the two outputs. Probe loading matters in both differential and common mode. Two arbitrary 50 Ω scope inputs to ground can look like 100 Ω under ideal differential drive while adding a path for common-mode current. Adding instruments to a populated board can also reduce the effective differential impedance. Use a suitable high-impedance probe or a verified fixture.
If subtracting two single-ended traces, verify channel gain, offsets, and deskew. Feed a common check signal and verify the residual. Common-mode changes can otherwise masquerade as differential signal. A probe displaying only the difference may not report the individual levels. Use appropriate synchronized measurements relative to the same local ground where common-mode data are needed. Keep a view of both plateaus and transition behavior, not just an automatic peak-to-peak marker.
Check the actual receiver path
At 125 MHz the period is 8 ns, with about 4 ns per state in the ideal case. Mark a stable region away from reflections and overshoot. Check separate transient limits if needed. Keep plateau swings and brief excursions distinct. If the two states differ too much, compare the oscillator under the prescribed termination with the final receiver plane. Swap measurement channels and retain consistent polarity to see whether a discrepancy follows the bench.
Log both single-ended traces, differential plateaus, VOD magnitudes, VOS states, and termination. For system acceptance, also check receiver thresholds and common-mode limits. Frequency and a full-height differential trace do not prove that all interface requirements are met. Use the same measurement when comparing a replacement ordering code or lot.
Compare a second capture with symmetric plateaus at +380 and −380 mV. It has the same peak-to-peak value of 760 mV, but almost no mismatch between states. A report giving only peak-to-peak cannot distinguish the captures. Save distributions for each plateau to check whether one state changes with supply, temperature, or location.
Measure plateaus at equivalent offsets from their transitions. Taking a point close to the edge in one state and near the middle in the other can turn ringing into a false imbalance. Evaluate several cycles and check whether the difference correlates with other output activity, receiver loading, or switching power.
Where supported, use a verified differential source to check the bench first. If the discrepancy appears in the same channel, inspect channel offset and input loading. Identify the source and receiver planes separately. Record termination and output drive conditions, and preserve raw traces before changing probe settings.