A multichannel acquisition board uses a 125 MHz LVPECL crystal oscillator at an LTC6954 clock distributor. Two sample clocks divide the reference by four. A synchronization command makes their relative phase repeatable, yet the acquisition system reports a clock loss. The reference remained continuous. One distributor output stayed low during synchronization. Check which channels joined the operation and whether their destinations tolerate the resulting gap.
Synchronization gates the selected outputs
ADI gives each LTC6954 output an independent SYNC_ENx setting. For a single standalone device, the SYNC input requires a high pulse of at least one millisecond. The device retimes the command to its reference. Each participating output reaches a normal falling edge, stays low, and restarts when the internal synchronization signal releases it. Runt-pulse prevention still leaves a long gap between intact pulses.
A 125 MHz LVPECL crystal oscillator has an eight-nanosecond nominal period. Dividing by four gives 31.25 MHz and 32 nanoseconds per period. Approximately one millisecond of hold time represents about 31,250 ordinary output cycles. Measure the actual interval because its endpoints depend on pulse width and edge alignment. A clean first edge after release can still arrive too late for a downstream clock-loss monitor. A frequency counter reading 31.25 MHz after restart does not show what happened during the interruption.
Delay increments follow the input clock
Synchronization can set a deliberate phase relationship. The data sheet gives DELx from zero through 63 input-clock periods. Enable synchronization on two divide-by-four outputs and set their delays to zero and one. The second starts one input period, eight nanoseconds, after the first. That is one quarter of the 32-nanosecond output period, or 90 degrees. If both outputs divide by eight, one delay count still represents eight nanoseconds, while the output period is 64 nanoseconds. The same count now represents 45 degrees even though the 125 MHz source is unchanged.
Capture SYNC, the last old edges on both outputs, and the first new edges. A steady-state phase plot wraps by an output period, so it cannot always identify which edge restarted first. Measure from the common synchronization event to establish the programmed delay. Use steady-state captures as separate evidence of receiver phase and long-term stability.
Qualify the branch that must remain continuous
An acquisition channel may tolerate a planned stop even if a management clock cannot. ADI recommends clearing SYNC_ENx on an output that must remain undisturbed. It then stays outside this gating operation and does not acquire a new phase from the same request. Synchronize the two ADC branches if their restart phase matters. Prevent the acquisition logic from accepting samples during the gap, and verify that a separate management branch remains available.
Compare the configurations with all branches participating and with the management clock excluded. Record the permitted gap, the condition for accepting data again, and the relative phase. First verify a zero-delay comparison, then add the required increment. Calibrate probe and fixture skew for fine measurements and repeat at the actual receivers. Their traces and crossover voltages still contribute error to the programmed phase.
Test the intended cold startup and any manual synchronization that may occur during service. A live restart can require flushing buffers, retraining, or rechecking lock. When comparing two 125 MHz LVPECL crystal oscillators, keep the input termination and SYNC sequence fixed so a planned clock interruption is not attributed to a new oscillator.
The first data after the gap needs its own check. Processing clocked from a gated branch may only notice an interruption after the clock resumes. Signal the planned operation to a control domain that continues to run, stop accepting data, and then trigger synchronization. Verify a real receiver clock or ready indication before resuming acceptance. Try an intentionally longer synchronization as a comparison. A timer driven by the stopped branch can disagree with elapsed time on the instrument.
Verify the integer delay at the distributor pins and compare it with the phase at the ADC. A connector, level translator, or longer trace can change the receiver result. Keep trigger and probe assignments consistent. Specify source frequency, levels, and jitter separately from the distributor's output cadence and permitted gap, particularly where service can trigger a live resynchronization.