When does an LTC2387-18 using a 125 MHz reference need two lanes?

An imaging board uses a 125 MHz active crystal oscillator as the FPGA reference. The FPGA divides that clock to trigger an LTC2387-18 conversion and supplies a differential burst at the original frequency to shift out the result. Single-lane reads work at a low sample rate and occasionally fail near the least significant bits at a higher rate. Two-lane mode distributes the result across two pairs. It changes the burst length and bit mapping, so check both against the usable readout window.

Follow conversion and readout as separate events

ADI specifies that a rising CNV edge initiates sampling and conversion. Conversion uses an internal clock. External CLK shifts out the resulting word, while DCO echoes the shift clock toward the receiver. A healthy waveform at the 125 MHz active crystal oscillator confirms the FPGA reference. The capture still depends on when CNV and the first CLK edge reach the ADC and whether the FPGA captures both DCO edges correctly.

One lane carries an 18-bit word on DA using nine CLK pulses. With TWOLANES selected, DA and DB carry bits in parallel, and the timing diagram uses five pulses. Follow which bit is assigned to each edge and lane. Concatenating all DA samples before all DB samples would not reconstruct the serial word. The first rising CLK edge for a result can occur at least 65 nanoseconds after that conversion's CNV edge. The last falling edge must arrive no later than 49 nanoseconds after the following CNV edge. Readout may overlap the beginning of the next conversion.

Calculate the first and last edge

Assume the logic derives one CNV event every ten periods from the 125 MHz active crystal oscillator. That gives 12.5 MSPS, with 80 nanoseconds between events. The shift clock is 125 MHz with a nominal eight-nanosecond period, four nanoseconds high. From the first rising edge to the ninth falling edge is eight full periods plus one half-period, or 68 nanoseconds. Even a first edge at 65 nanoseconds puts the last one at 133 nanoseconds. The latest acceptable time is 80 plus 49, or 129 nanoseconds. This ideal single-lane example exceeds the limit by four nanoseconds.

In two-lane mode the first rising edge to the fifth falling edge occupies four periods and a half, or 36 nanoseconds. If the first edge is nine reference periods after CNV, it lands at 72 nanoseconds and the last edge at 108 nanoseconds. That leaves 21 nanoseconds before the deadline. These times apply at the ADC pins. Clock gating, buffers, trace mismatches, and edge displacement consume margin. Substitute actual clock frequency and duty cycle if they differ.

Verify the ADC input interface and CNV pulse-width limits as well. Document the CNV divider, shift burst count, and relative launch time separately. A divider change may leave the burst count correct while shrinking the window for that burst.

Verify known data before testing the analog input

Enable TESTPAT as described in the data sheet. The two interface modes emit different known words. Count the actual pulses and capture DCO, DA, and DB at the FPGA. Check the recovered bits against the selected mode's pattern. Disable the pattern and use a known analog input to confirm that the next records are real conversion results. Apply the data sheet's startup conditions, including its instruction that the first two conversions after power-on or power-down exit are invalid.

Record the timing margin on each receive lane for both DCO edges. A connector, termination, or receiver delay can affect one lane before the other. A known word checks bit ordering and basic timing. Sustained capture at the planned rate and temperature range checks repeatability. If the test pattern remains correct while live codes vary with the CNV source, investigate conversion-edge jitter and analog settling separately. Specify the 125 MHz active oscillator against the trigger requirements and qualify the burst and lane alignment at the readout interface.

If the connector has room for only one data lane, a faster burst is another candidate. A clock manager could double the same FPGA reference to generate a 250 MHz burst. At 50% duty cycle, the first rising edge through the ninth falling edge takes 34 nanoseconds. A first edge at 68 nanoseconds would finish at 102, or 27 nanoseconds ahead of the 129-nanosecond deadline. The receiver would now sample on edges only two nanoseconds apart. Requalify termination, clock-to-data skew, and capture settings. A delay setting that passed the slower two-lane configuration does not establish that the faster one-lane route passes.

At 12.5 MSPS, recording 18 bits per sample gives an average payload of 225 million bits per second. That figure sizes downstream memory or storage. The capture interface receives a full word in a short burst and needs the instantaneous edge timing. Save separate test records for sustained storage throughput and the readout burst. If the board supports both modes, use the same analog input when comparing reconstructed words and dynamic performance.