Two acquisition modules exchange data over a backplane through TLK2501 transceivers. The transmitter uses a 125 MHz active oscillator. Known data passes. As soon as the payload stops, host software reports a disconnect and immediately recovers at the next transfer. Check whether software equates a low receive-valid signal with loss of signal. The shared pin has different meanings across operating states. Examine the error and data outputs along with mode to distinguish valid idle traffic from loss of input.
Identify reference, encoded line rate and receive status
TI describes a transmitter that accepts 16 parallel bits per GTX_CLK and encodes them into 20 serial bits. With a 125 MHz active oscillator supplying the transmit reference, the period is 8 ns. Twenty bits per reference cycle give 2.5 Gbit/s on the line. Sixteen data bits per cycle give up to 2.0 Gbit/s of parallel payload before idle, control codes and framing. The latter figure assumes data on every cycle. State which rate is being measured before comparing it with application throughput.
The receiver also has a recovered clock. The 125 MHz label at the transmitter cannot establish receive input amplitude, timing recovery, code health or parallel capture. Even the expected recovered frequency is only one observation. Start with identifiable data and check that receive data and status align in the receive clock domain. A frequency counter cannot tell whether a cycle represents payload or idle.
Interpret the three bench cases from the status table
In normal operation the data sheet lists both RX_DV/LOS and RX_ER low for idle. Normal data drives valid high and error low. Carrier extension and error propagation have their own combinations. Idle should not be written into a payload buffer, but the receiver is still seeing valid idle codes and can remain linked. Software that starts link recovery every time valid goes low will repeatedly restart during normal gaps.
TI describes loss of sufficient input amplitude in enabled operation as valid/loss, error and all data outputs going high. Error propagation also raises both status pins, so those alone cannot distinguish it from loss. Stop payload while keeping valid idle first. Then test controlled input removal and capture status, data and receive input. A coding error and deliberate loss of input exercise different conditions. Identify any special test mode before applying the normal payload interpretation.
In power-down the shared pin acts as a signal detector. It is high with sufficient signal and low with insufficient signal. The receive data bus and error output become high impedance. If software keeps sampling those pins as if the device were active, board bias can masquerade as an event. Keep actual enable state with each capture and use it before decoding status.
Test recovery with identifiable payload
Run continuous data, idle with the source still transmitting, and disconnected input. Save the raw status in the receive clock domain before checking the host's classification. On recovery send a known starting word and verify it is captured once. If the peer still sends idle while the host reports loss, compare status with the data sheet at the first disagreement. If a true loss is filed as ordinary idle, verify that error and enable are sampled with the shared pin.
Swap the modules and run the same comparison in the opposite direction. This can show whether the symptom follows a transmitting board or remains with one receiver. Record the actual cable or backplane, termination and signal amplitude. Keep the first events after a controlled interruption, before the application display replaces them with later ones.
Short payloads can expose a software observation problem. Count valid, idle and error cycles separately in the local receive clock domain, then report all three over one fixed window. Transmit two equal blocks from the same source with a longer idle interval between them. If raw word counts remain correct while the display flashes disconnected, follow the status event across clock domains and into host interpretation. Save a timing marker so the log can be aligned to the capture.
Record the 125 MHz active oscillator interface, transmit and recovered clocks, and the data and status for idle, payload, loss and recovery. Establish that a known block arrives and that normal idle retains the expected link state. The same evidence can then distinguish a physical change from a status interpretation error after a replacement oscillator or backplane revision.