A USB bridge uses an FT232H with a 12 MHz passive crystal and enumerates successfully. A local controller exchanges data in FT1248 mode. One bridge works, but the idle status becomes unreliable after two devices share data lines, even though some selected transfers succeed. Identify which device drives each wire while selected and while idle. FT1248 is half-duplex, and data and status can reuse wires in different phases.
Separate idle status from acknowledgment during a transfer
With idle flow control enabled, the FTDI data sheet describes write-buffer status on bidirectional MIOSIO[0] and read-buffer status on MISO while chip select is inactive. An active transaction begins with command and bus width, followed by data. During the data phase MISO reports acknowledgment for transferred bytes, while data uses the bidirectional lines. Record the select level when interpreting MISO. Treating it as a conventional serial receive data wire can confuse idle status or acknowledgment with the requested byte.
When two devices share the bus, the manufacturer warns that idle buffer status cannot be driven by multiple unselected devices without contention. Idle reporting can be disabled. That setting is separate from the selected transfer's acknowledgment. Check the EEPROM settings of both chips for FT1248 and the appropriate idle reporting option. Separating the two chip-select signals alone does not establish exclusive ownership while both are inactive. Verify the documented shared-bus configuration and then test acknowledgment during selected transactions.
Compare each device alone with the dual-populated assembly. If the fault appears with both selects inactive, capture the shared wires, select signals and supplies. A fixed digital value can hide two drivers with unequal strengths. Observe actual voltage and edges before changing polling speed. Establish the correct configuration before repeatedly exercising the bus.
Include the turnaround clock in one-bit timing
In the documented one-bit flow-control mode, the command uses seven clocks, the eighth is for turnaround, and a data byte uses another eight. Suppose the local controller drives SCLK at 5 MHz. The first eight clocks and one data byte total sixteen clocks, or 3.2 µs. A second acknowledged byte in that transaction adds eight clocks, or 1.6 µs. Check chip-select margins and the physical handoff against the timing diagram. The 12 MHz passive crystal supplies the FT232H reference. The local controller provides the sample 5 MHz SCLK.
For reading, release the bidirectional wire after the command so the bridge can drive data. A write also needs the specified release near its end to return ownership for idle feedback. Capture the controller output enable and chip select and mark where the data settles. If the last bit is unreliable or the next transfer fails to start, check whether either driver stayed enabled. FTDI says to abort the current selection on NAK. Record which bytes completed and let the application protocol determine where a retry is valid.
Check which width the bridge sees on the first active command edge. The data sheet uses low levels on groups of bidirectional pins to select one, two, four or eight bits. Unused lines must retain the prescribed high levels. A new carrier board that pulls an unused pin low can therefore change the effective width. Probe the actual command phase after selection. Idle status does not identify the command input. An analyzer attached only to MIOSIO[0] can miss the unwanted low level. Check the fitted pull-ups and relevant EEPROM settings.
The same fixture can distinguish buffer pressure from contention. Use host transfers with deliberate pauses and first test one bridge. Exercise a buffer that can accept another byte, then cause a NAK and verify that the controller ends the active selection. Repeat on the shared assembly and check whether the unselected bridge influences the status line. Record the bytes actually accepted. The application's sustained throughput also depends on USB scheduling and buffering, apart from the local SCLK rate.
Record both the crystal circuit and the bus result
Retain a single-device trace and another from the shared assembly. Include ownership, idle reporting configuration, command, status and data. Exercise both buffer statuses instead of leaving one constant throughout the test. Qualify a replacement 12 MHz passive crystal against the installed load, startup and frequency. If USB enumeration succeeds while local transfers still fail, use the same external serial clock and test data to confirm idle ownership and turnaround.