Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / System Validation and Replacement

Does a CS4344 need a different master clock to switch from 48 kHz to 44.1 kHz?

An older audio board plays a 48 kHz recording correctly and goes silent or sounds wrong at 44.1 kHz. Its 12.288 MHz active oscillator looks stable on a frequency counter, and the software has changed the left/right clock. Measure both clocks at the DAC and compare their ratio with the data sheet. The CS4344 automatically configures its speed mode from the master clock and its relationship to LRCK. A stable oscillator does not establish a valid pair of clocks.

A fixed master clock supports several rates within one family

The manufacturer's table lists standard combinations of MCLK and LRCK. With a 12.288 MHz active oscillator, the ratio is 256 at 48 kHz and 128 at 96 kHz. Both combinations appear in the table, although they use different speed modes. Keeping the same MCLK at 44.1 kHz gives approximately 278.64. It is noninteger and is not a supported combination for that rate. At 44.1 kHz a ratio of 256 calls for 11.2896 MHz. Equipment promising native output at both 48 and 44.1 kHz needs a valid clock pair at the converter for each setting.

Check the opposite case as well. If the hardware keeps 12.288 MHz and divides it by 256 to generate LRCK, the converter receives 48 kHz regardless of the file's label. It can produce audio if the 44.1 kHz file's samples are just queued in order. With no sample-rate conversion, playback runs at 48 divided by 44.1, roughly 8.84 percent faster. A 1 kHz tone becomes about 1,088 Hz. Wrong pitch and duration distinguish this case from an actual 44.1 kHz LRCK paired with an invalid ratio. Save the file's declared rate and the rate measured at the DAC pins.

A product with a fixed output rate can use sample-rate conversion in the host and retain one valid set of clocks. A native-rate design can use two clock sources or a generator that supports both rate families. Choose according to available processing, muting requirements during a change and the promised output rates. The data sheet also requires MCLK, LRCK and the external bit clock to be synchronous even though no fixed phase relationship is specified. Separate references can look accurate on a counter without meeting that condition. Trace the clock tree to each pin and confirm which component generates each clock.

Capture the ratio and the switching transient separately

Save a steady-state capture at both rates. Play moderate, distinct left and right test signals of known duration before switching. This verifies sample rate and channel mapping. If individual MCLK edges are hard to count, count them over a window spanning several complete LRCK periods. Check absolute MCLK frequency in addition to the integer ratio, since both help the device configure its internal clocks. Capture MCLK with LRCK first, then take another capture of LRCK with the bit clock and data. Use the serial format of the installed part. Other suffixes in the family use different alignment.

A small switching noise can remain even when both clock combinations are valid. Cirrus recommends sending zero or near-zero data for at least ten samples before changing the clock ratio or rate. Ten samples at 48 kHz take about 208 µs. At 44.1 kHz they take about 227 µs. A software mute request may still be queued in an audio buffer. Verify that zero data actually reaches the converter and measure its timing relative to the first changed clock edge. The calculated interval is the preparation time before the switch. Output recovery requires a separate check on the assembled board using the manufacturer's timing guidance.

Record the first power-up interval separately. The data sheet describes roughly 2,000 sample periods before audio appears once valid LRCK, data and any external serial clock in use have arrived. At 48 kHz those periods account for about 41.7 ms. The quiescent reference voltage also ramps according to external capacitance, with typical times listed for different capacitor values. If the board is tested with a short sound immediately after power-up, the missing beginning may reflect startup time. Under the same power and mute conditions, run a separate rate switch after stable playback. This distinguishes waiting for startup from presenting the wrong clock pair. The power-up figure is not a fixed delay for every in-service rate switch.

Keep three records for a repair handoff. Identify which clock source drives MCLK at each rate, save the ratio with measured output pitch, and capture the interval from the first mute to the return of the set output level. The 12.288 MHz active oscillator works for both 48 and 96 kHz in these examples. For another rate family, calculate the ratio before choosing a clock arrangement. Cirrus Logic marks the CS4344 family discontinued. These checks apply to diagnosis and acceptance of installed equipment. Check the original supply, signal levels and routing before replacing the oscillator on a board.

References

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.