Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Measurement and Acceptance

A 156.25 MHz LVDS oscillator is clean until its neighbour starts. How can you test for crosstalk?

Two differential pairs run in parallel through a connector. The receiver's zero crossings look steady with only the 156.25 MHz LVDS oscillator running. Once the neighbouring data lane starts sending continuously, the clock edges split into two groups while the counter's frequency display stays almost unchanged. To check for crosstalk, turn the suspected source on and off in a repeatable way while keeping terminations, clock source and supply conditions controlled.

Look for a repeatable timing relationship on the powered board

Measure P minus N at the clock receiver with a differential probe of known bandwidth and loading. Use the same crossing threshold and time reference when recording clock time error with the other lane quiet and transmitting a specified pattern. Capture an independent activity marker or source timing reference so the scope does not use the very edge under test as its timing baseline. Check probe proximity to both lanes and measure the setup background first.

Try a different repeating aggressor pattern and see whether the 156.25 MHz LVDS oscillator's edge errors rearrange with it. Keep appropriate termination on the idle lane. Pulling a whole module can change both termination and reflections. Switching off a shared rail can also change supply noise. If complete module shutdown is the only available control, take a second set of records with similar power demand and a changed data pattern, and record the shared rail.

With two nearly synchronous clocks, relative phase matters. Crosstalk may appear as a slowly drifting offset rather than obvious edge spread in a short record. Step a controllable source through relative phase, or introduce a small permitted frequency difference and capture a complete beat interval. If product units cannot be detuned, change an available transmit pattern or vary initial phase and record the relative timing actually covered.

Separate near-end and far-end coupling in a passive fixture

Disconnect the transmitters and receivers or use a passive coupon that represents the same layout and connector, then attach the network analyzer. With the excitation end of the driven pair as a reference, measure near-end crosstalk at the corresponding end of the other pair and far-end crosstalk at its opposite end. Keysight examples use SDD31 and SDD41 for these paths. The names depend on the port map. Each logical differential port needs two physical single-ended ports. Verify mixed-mode definitions, reference impedances and termination of unused ports, and keep a photo of the actual mapping.

Measure the fixture background first. With independent adapters and termination, check how much leakage remains between otherwise separate paths across the band of interest. If the sample trace is close to that floor, report the resolution limit. Move reference planes to the coupon where practical. Parallel traces on an adapter can couple on their own. Substitute the connector, dense via section or parallel trace sample individually to see which section reproduces the behaviour.

The sweep for a 156.25 MHz LVDS oscillator with fast loaded edges must cover relevant edge content. A measurement at the nominal frequency alone can miss a coupling peak. Save complex frequency-response data for an actual-edge estimate, or use a representative repetitive step to observe a coupled pulse. Recheck both passive coupling and powered-board edge error after changing connector placement or trace length.

Translate a measured voltage disturbance into a timing allowance

At a single test frequency, −40 dB of differential coupling represents a voltage-wave ratio of 0.01. With matched impedances and a 350 mV differential tone, the corresponding coupled amplitude is about 3.5 mV by the same amplitude convention. That estimate applies to the tone. Measure the operating disturbance separately because clocks and data contain many components. For a measured 3.5 mV disturbance near the receiver threshold and a local slew rate of 0.35 V/ns, the first-order edge shift is 0.0035 ÷ 0.35 = 0.010 ns, or 10 ps.

If the allowed absolute edge displacement from neighbouring activity is 8 ps, compare the largest absolute displacement using the chosen baseline. A measured 10 ps worst case fails the simultaneous-operation budget. Mean edge displacement can stay small when some edges move earlier and others later. Label the two groups with the transmitting lane's activity, then decide whether to investigate trace separation, connector pins, shared supplies or return paths.

For a final cross-check, keep the other lane active and drive the same receiver through an independent short route at comparable levels and edge rates. If the disturbance disappears with the original route, board routing, vias and connectors deserve priority. If both routes show the issue, check the recorded rail, probe background and receiver buffer. Archive the exact failing stimulus, jitter definition and setup so a replacement oscillator can be qualified against the same use case.

On an engineering sample, route the same stimulus in turn through the original neighbour and a more distant pair if available. Compare their effects on the same clock crossing with equivalent drive and termination. A pin reassignment can preserve an apparently good bit-error rate while leaving much less timing margin. Retain receiver edge timing and the raw terminated waveforms.

References

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.