After a receiver board revision, a 156.25 MHz LVDS active oscillator still locks but differential swing falls substantially. The source test board is unchanged. Trace every resistor across the pair, including configurable receiver termination and measurement fixture loading. A schematic showing one resistor can conceal another active termination. Verify the actual loading before selecting a higher-swing alternative.
State which differential amplitude the report uses
Use a simple current-drive model with 3.5 mA after each polarity reversal. A 100-ohm receiver load gives positive and negative plateaus of about 350 mV magnitude, or 700 mV differential peak to peak. A second 100 ohms in parallel makes 50 ohms. Ideal plateaus fall to ±175 mV, or 350 mV peak to peak. Check whether the report quotes a single signed plateau or the range between both. A definition error can also produce a factor of two.
TI's LMK00306 data sheet describes termination and coupling for LVDS outputs. For a suitable DC-coupled path the across-pair termination goes near the receiver. With two terminations, the driver can see half the impedance and the receiver swing can fall. The simple model establishes scale. Real drivers have compliance limits and load dependence. Different termination locations can affect plateaus and edges differently. Use the actual receiver limits for acceptance.
Verify which terminations conduct when powered
Check the board, connectors, and test fixture. If a receiver supports internal termination, read its configuration and confirm where the feature is active across power modes. Verify full device suffixes. Some members include a resistor and others require one outside. A populated optional resistor with internal termination enabled creates a duplicate load. AC coupling can hide that load from a power-off ohmmeter.
First make a control capture without disturbing the intended termination. Use a suitable high-impedance differential probe near the receiver. Check common mode against both probe and receiver limits. Connecting two 50-ohm single-ended inputs can add differential loading and unwanted common-mode paths. Use such a connection only where the measurement plane and loading are explicitly defined. Probe capacitance can also change fast edges. Retain a control when changing probes.
Where allowed, change only the internal termination setting or compare two controlled board builds. Preserve the single intended line termination. Keep enables, supply, and receiver conditions fixed. If restoring the intended load restores swing at the same frequency, duplicate termination is supported. If the 156.25 MHz LVDS oscillator still has weak plateaus, examine supply, output standard, and interconnect loss.
Separate plateau loss from reflections around an edge
With both resistors near the receiver, the parallel model is straightforward. If one is near the source and the other remote, propagation and reflection can change different portions of a pulse. Capture complete periods. At 156.25 MHz one cycle is 6.4 ns. A two-nanosecond reflection round trip can fall within the same half-cycle and affect how long the waveform remains valid after crossing. Verify actual timing from the path and waveform.
Save differential traces at source, receiver, and fixture port. Align with the same trigger and locate the amplitude change. If it happens only with the fixture, bypass it or use a qualified high-impedance point, then repeat after reconnection. If distortion clusters around a single reflection, investigate layout and impedance before changing oscillator drive.
Record standard and actual loading during substitution
Keep the result under the oscillator's specified termination and the receiver result in the real configuration. Record internal termination, external parts, coupling, extra fixture loading, and amplitude definition. Two 156.25 MHz differential oscillators can pass standard loading and behave differently on an over-terminated board. Compare after fixing termination, or qualify unusual loading within vendor limits.
A lower swing may appear only after switching modes. Include required startup, steady operation, and low-power recovery. Read back termination after recovery and compare it with the default. Preserve configuration, board revision, and the waveform so future device swaps can repeat the same electrical conditions.
Measure the center of both plateaus across several periods and save peak-to-peak voltage and overshoot separately. A peak-to-peak result that includes overshoot can look healthy even when duplicate termination lowers the sustained levels. Recompute using the receiver's amplitude definition and preserve the window so a second station measures the same part of the pulse.