A chassis carries a 156.25 MHz LVDS clock from an oscillator to a remote receiver. A repeater with equalization makes the received edge steeper, but the crossing moves around more. Equalization can compensate high-frequency channel loss while also changing the way noise and reflections reach the receiver. Evaluate edges over the long route, ringing over the short route and actual timing at the load. Accurate oscillator frequency alone cannot establish those results.
Identify the segment requiring compensation
TI's DS25BR100/101 data sheet separates receive EQ from transmit pre-emphasis. EQ changes what the buffer receives after the preceding channel. PE changes what the buffer launches into the next channel. Draw the two routes and document their terminations. TI's jitter tables use particular channels, amplitudes, common-mode levels and signaling rates. They do not state the resulting jitter of a 156.25 MHz clock in the enclosure's cable. A repeated clock also differs from randomized data patterns. Test the real frequency and route.
At 156.25 MHz a period is 6.4 ns, with nominal 3.2 ns halves. Edges include higher-frequency components. Suppose two channels both lose 1 dB at the fundamental, but at 781.25 MHz, the fifth harmonic, they lose 2 dB and 8 dB respectively. That passes about 0.79 and 0.40 of the voltage amplitude of that component. The difference can change edge shape. Channel phase response still matters, so those points do not predict the detailed waveform. Establish that high-frequency loss is actually the limiting effect before increasing compensation.
Make three observations
Record the oscillator with its recommended load, the repeater input after the first channel and the actual receiving pin. Start with low EQ and PE disabled, then change only EQ before testing PE. Keep thresholds, probes and fixture loading consistent. The DS25BR100 has integrated 100 Ω input termination while DS25BR101 omits it. Replacing a 101 with a 100 while retaining the old external load can mix a termination change with the apparent equalization improvement.
Use the same timebase and measurement point when comparing jitter. In a local linear approximation, 10 mV of differential threshold disturbance on a 0.25 V/ns edge corresponds to about 40 ps. A new setting doubling slope to 0.5 V/ns but increasing disturbance to 25 mV can instead give about 50 ps. This scale check does not replace actual time-interval error or phase-noise measurements. Check for a second threshold crossing where ringing is strong. A fastest edge and quietest reading from different observations are not one waveform.
Test the short and long installations at one candidate setting
Use the shortest and longest supported cables with the intended output and receiver terminations and test supply and temperature limits. For short cables, look for ringing or false edges after high-frequency boost. For long cables, measure minimum pulse widths, crossing time and downstream lock. If phase noise matters, use the same integration range and setup. Capture more than one assembly point before extending the setting to cable, connector or buffer substitutions.
If the product uses a single EQ setting, demonstrate that it covers both cable lengths and passes real traffic or acquisition. If populations use different settings, keep the cable type, length, buffer suffix and validated condition with each configuration. An oscillator request should include 156.25 MHz LVDS, supply, package and source jitter. Board acceptance retains the worst timing and functional result for each EQ setting.
If existing records only count data errors, capture the reference and data status together through a temperature change. A steeper edge does not by itself establish continuous data delivery. Requalify noisy crossings in the actual use conditions before carrying the setting to another assembly.
Keep comparable captures before and after thermal soak. If the change already exists at the buffer input, investigate the cable, connector and route. If input remains steady while the output changes with buffer temperature, review the selected setting and supply. If the waveform only degrades when the real receiver is attached, examine termination, receiver threshold and probing. Use the same definitions across observations.
Qualify different cable suppliers separately even for equal length and appearance. Check repeated crossings on short runs and minimum slew and successful capture on long ones. Tie each cable to the tested buffer setting. A future replacement can then be exercised in the documented worst configuration.