Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / System Validation and Replacement

Can the buffer’s VBB pin terminate the output of a 156.25 MHz LVPECL clock path?

A board uses a 156.25 MHz LVPECL oscillator followed by an MC100EP16. The buffer offers a pin named VBB, and the output termination also needs a reference potential. Reusing one net looks economical. Check the circuit attached to each first. VBB provides a local input switching reference and can bias AC-coupled inputs. The output termination potential must absorb current from the differential outputs. Required voltage and current differ.

Check the voltage first

The onsemi MC10EP16 and MC100EP16 data sheet limits VBB to local use. In single-ended use it can bias the unused differential input, and it can rebias AC-coupled inputs according to the manual. Use the specified 0.01 µF bypass between VBB and VCC and limit sourcing or sinking to 0.5 mA. At a 3.3 V supply, the MC100EP16 PECL table gives a typical VBB of 1.875 V. Its output-level specification uses each output loaded by 50 Ω to VCC−2.0 V, equivalent to 1.3 V in this case. The two working voltages differ by 0.575 V. Combining the nets changes both intended operating points.

The typical high and low outputs in that table are 2.280 V and 1.480 V. Through the specified resistors these correspond to about 19.6 mA and 3.6 mA. With one line high and the other low the sum is about 23.2 mA. If output levels stayed unchanged with 1.875 V termination, the high leg would deliver about 8.1 mA into that node and the low leg would draw about 7.9 mA from it. The contributions can partially cancel. Single-leg loading, edge skew and actual output levels change the net flow. This model does not establish that VBB can support the load within 0.5 mA. The manufacturer specifies VBB for input bias.

Check the termination supply’s sink capability

If the design uses a dedicated 1.3 V termination rail, verify it can sink output current. A regulator that only sources current can rise when the outputs deliver current into it. For an approved resistor network, calculate both open-circuit equivalent voltage and parallel impedance with actual rail and tolerance values, then check static consumption. Confirm the oscillator, buffer, route and receiver requirements together. The buffer's output test load applies to that buffer. Check the upstream oscillator's termination against its own documentation.

Also verify location and return paths. At 156.25 MHz one period lasts 6.4 ns. Route and stub reflections can produce multiple events inside that period. Determine whether a fixture's 50 Ω instrument load is AC coupled or adds another DC path to ground. Capture VBB, the termination rail, and the actual input voltage. A probe should not change the DC bias and then make the oscillator look at fault. Where VBB biases inputs, also consider leakage from instruments and fixture circuits against its limited available current.

Record both nets for sample acceptance

Name the input and output bias nets distinctly in the schematic. Save their settled levels during first-article test and capture changes during startup, authorized mode changes and power recovery. Verify amplitude, duty and common mode at the receiver. If one termination rail serves several outputs, calculate and measure its load with the maximum intended active set. One visible clock does not establish that shared bias remains valid when other outputs are added. Preserve the oscillator and buffer suffixes, both terminations, load currents, and the receiver trace for any later frequency-compatible substitution.

For an approved passive divider option, nominal values also provide a check. On each line, 130 Ω to 3.3 V and 82 Ω to ground give about 1.276 V open circuit and 50.3 Ω in parallel. This is close to the 1.3 V and 50 Ω test condition. Check actual tolerances and supply limits, and recalculate for any 2.5 V version. Save the population and measured voltage with the output result.

Check the interval when the buffer is active and the receiver is still off. If receiver power also supplies the termination reference, the load takes on a different DC state. Document rail ordering, what output state the buffer can drive at that point, and what voltage the receiver accepts unpowered. A constant termination voltage cannot be assumed across module insertion or startup.

For first-article test, remove optional debug leads first. Capture termination bias, buffer power and downstream reset. Reconnect the intended fixture in the specified manner after verifying the steady state. If VBB biases AC-coupled inputs, compare the first received pulse sequence with settled behavior without changing coupling between tests. Qualify both the recommended load and the consumer's actual state.

With several buffers sharing one termination rail, capture one enabled buffer and then the maximum enabled population. Observe the turn-on and thermally settled values. Save the old reference, measured resistor population, and rail waveform if a later buffer substitution changes the output.

References