Why an AD9513 divide-by-five output can have only 40% high time

An acquisition backplane feeds an AD9513 from a 156.25 MHz LVDS oscillator. A divider supplies 31.25 MHz to a digital interface. The frequency counter is correct, but a revised receiver sometimes fails. Check receiver minimum pulse widths against the documented duty cycle. Divide-by-five can put only 40% of the output period high. Halving the period overestimates the available high time.

Use the applicable divider table

AD9513 has three configurable outputs. Its tables depend on which pins and mode are selected. A pin used for a divider setting in one mode can select phase in another. Find the relevant output and mode first. In the OUT1 divide column of Table 15, the divide-by-five entry has 40% duty cycle. High time is 40% of the full period. Record the divider and duty together.

The configuration pins use more than two level choices. Check the actual strapped level against the documented ranges and board network. A simple logic reading may not identify the intended row. Confirm the expected divider on the named output, then measure high and low separately. A frequency counter cannot establish their proportions.

Calculate the shorter output interval

The 156.25 MHz LVDS oscillator has a period of 6.4 ns. Five periods produce a 32 ns output cycle, or 31.25 MHz. Forty percent gives nominal high and low durations of 12.8 ns and 19.2 ns. Assuming 50% would incorrectly predict 16 ns for both. Suppose the receiver requires each width to be at least 14 ns under its operating conditions. The high side is about 1.2 ns short even though low time is ample. This uses a nominal setting and an illustrative receiver limit.

Measure the short interval at the receiver. For a differential clock, use the applicable differential crossing instead of a single-ended midpoint. For a single-ended path, use its receiver threshold. Routing, termination, common mode and threshold can affect the observed interval. Compare at the source under appropriate termination and at the actual receiving point. Keep minimum width over many cycles rather than only an average.

Preserve the frequency when comparing an alternate design

If the product needs 31.25 MHz and nearly symmetric output, evaluate an allowed alternative. A suitable 312.5 MHz source with the same table's divide-by-ten setting yields 31.25 MHz with nominal 16 ns high and low. That is an arithmetic option. Verify source compatibility, rate, clock quality and receiver margin. Switching only to a different even divider with the original input changes frequency as well.

When comparing two outputs of the same intended frequency, hold voltage, termination and measurement conditions fixed. Record the shortest high and low intervals at source and receiver. Test the first cycle separately if the system depends on it. Run real data in addition to clock measurement to confirm that the receiving device operates under the intended conditions.

If startup is the only failing case, capture the supply and strapped selection levels before stable operation. A final level establishes the eventual mode only. Compare actual assembly options with the documented ranges and startup conditions, and separate captures before the receiver supply is valid.

With a suitable generator, hold frequency, amplitude, common mode and termination fixed and compare symmetric and narrower-high waveforms at the receiver. Compare both with the divided clock. A failure tied to the narrower high intervals under similar electrical conditions supports the diagnosis. If both fail, check the receiver's other requirements.

Record scope bandwidth and sampling. Multiple crossings or slow edges can mislead one automatic duty reading. Keep a multi-cycle trace and the interval with the shortest high time.

Keep the 156.25 MHz LVDS oscillator connection, selected divider row, output rate and pulse widths together. When the downstream part or termination changes, check both minimum pulse widths again. Clock frequency is one limit; the receiver also needs enough time on each side of the threshold.