The angle displayed from an AS5048A looks right when the rotary stage is stationary. As soon as the stage moves, the reading follows the other acquisition system by one polling interval. A 16 MHz active oscillator provides the controller timebase. Before replacing it, check the SPI transaction order. The sensor sends and receives concurrently. It returns a read command's result in the following frame. Assigning each received word to the command transmitted in the same frame can go unnoticed as long as the reading stays constant.
Associate commands with replies in the wire capture
The manufacturer's read diagram shows two serial frames. When the host sends the read command, the output contains the response associated with the previous command. The next transfer returns the result from that read while clocking in another command. Each sixteen-bit frame has its own CS-low interval. To check one angle read in isolation, send the angle-register read, deassert CS, and send a NOP frame. Associate the word returned during NOP with the previous request. Continuous polling can issue the next request while retrieving the preceding one. Track which command is outstanding, particularly after initialization, a pause or recovery.
On a stationary shaft, alternate reads of the angle and a diagnostic register, then send a NOP to complete the final read. Interpret the received word using the previous frame's address. Decode the individual diagnostic fields using the same manual. Display the transmitted word, received word and CS frame index together. A typical analyzer presents the two directions side by side. Without the frame relationship, that display can suggest a command and response belong together when they do not.
Calculate time on the wire and time per read separately
If the serial peripheral divides the actual 16 MHz reference by four, SCK is 4 MHz. Its period is 250 ns. Sixteen bits occupy 4 µs in serial-clock periods. Two frames account for 8 µs of bit time. The real time from assertion of the first CS to deassertion of the second also depends on the boundary intervals at both frames and the intervening CS-high time. The data sheet specifies at least 350 ns between transfers with CS high, at least 350 ns from CS assertion to the first rising SCK edge, and at least 50 ns from the last falling edge to CS deassertion. Do not clock a single continuous thirty-two-bit transfer merely because the NOP's outgoing data are unimportant.
In continuous polling, after the initial frame, each transfer can retrieve a previous result. That throughput differs from a series of independent two-frame reads. A design triggering a standalone acquisition every millisecond should complete both frames in that request. Software issuing only one frame each millisecond and labeling the reply with the command just sent can report an angle one poll late. At a uniform turn per second that interval corresponds to roughly 0.36°. An ideal fourteen-bit code step is 360° divided by 16,384, or about 0.022°. A frame-labeling error could account for more than a dozen counts at that speed. The sensor's internal measurement and processing delays are separate.
Check the reply before interpreting its angle field
The manufacturer's response format separates parity, an error flag and fourteen data bits. Check even parity and handle the error flag before accepting a measurement. Extract the fourteen angle bits without the two status bits. Compare angle differences across the zero crossing using wraparound. Treating a jump from a high code to a low code as a large reverse movement can obscure the frame-label issue. Begin with a stationary diagnostic capture, then move slowly through the zero position and finally change the polling interval. Watch whether the apparent lag scales with that interval.
Once the error flag is set, repeated angle reads do not clear it. Read the clear-error register as specified, receive the cause in the following frame and retain it with the capture that triggered the fault. The cause can be parity, an invalid command or incorrect clock count within CS. This diagnostic uses the same response pipeline. The old word observed in the frame that sends the clear request should not be labeled as the newly retrieved cause. Issue and correctly pair another angle read to confirm recovery.
Include a driver recovery check. Interrupt a request after the read frame, clear the software queue and start again. The first frame after restart may still contain a reply to an earlier command. The recovery procedure must associate it correctly or discard it. With two sensors, each chip-select line needs its own outstanding reply state. Sharing a serial clock does not fix replies assigned to the wrong device.
For a controller board with a 16 MHz active oscillator, confirm input voltage levels and clock wiring separately. Record SCK and CS timing, both frames of a standalone read, and the angle logged during real motion. Once the wire capture confirms correct pairing, investigate jitter, magnet alignment or sensor processing delay as needed. A more precise 16 MHz active oscillator does not turn the preceding angle reply into the one requested by this frame.