An industrial control board with a 16 MHz active oscillator receives another node's traffic and appears to queue its own messages normally. The host TXD moves, yet there is no matching differential drive from the board. On a board using the SN65HVD230, check the voltage at the transceiver's RS pin during a send attempt. This part can preserve its receiver in standby while disabling the driver. Actual receive traffic can therefore hide the operating mode.
Identify which node starts a transition
The controller drives the transceiver D input through TXD. The transceiver driver then creates the corresponding difference between CANH and CANL. In the reverse direction the receiver identifies dominant and recessive states and reports them on R to the controller's RXD. Capture D, R and the differential bus close to the transceiver. First send a known frame from a second test node and see whether R follows. Then arrange for that node to send less periodic traffic and let the board under test initiate a distinguishable frame. Activity on D with no corresponding bus drive narrows the investigation to the transmit path and its controls.
Trigger on a falling edge of D, keep time on either side and add RS to the capture. Terminate the test bus for the configuration in use and choose a suitable differential measurement. If other traffic occupies the capture, align it with the second node's send record. Aggregate bus activity obscures which board is transmitting, especially when both nodes have similar periodic schedules.
Calculate the standby threshold from actual VCC
Table 2 of the TI data sheet gives three configurations for the SN65HVD230. A strong pulldown on RS selects high speed. An appropriate resistance to ground provides slope control. A voltage above 0.75 times VCC puts the part in listen-only standby. For 3.30 V the latter boundary is 2.475 V. With 3.1 V measured on RS, the board can still see traffic from another node under that supply condition, but requests on D will not enable the differential driver. A reading near 1.8 V falls above the documented low region below 1.2 V and below the guaranteed high region for this supply. Use measured rail limits and the controlling output's guaranteed levels to check the margin.
Some boards pull RS down through a resistor and drive it high with a host GPIO. Check whether that pin starts in high impedance or push-pull, whether its multiplexing matches the design, and whether wake code restores the GPIO before submitting the first message. Mark the mode change and first transmit request separately. A capture from steady traffic can miss a failure limited to the first frame after wake.
Near a mode boundary, follow the schematic to identify the loads on RS. A development board with the pin hardwired to ground and a product board with a series resistor, level translator and pulldown represent different conditions. Record voltage at the transceiver pin and the host pin, then compare the installed resistors to the design. GPIO register readback shows the level software requested. The transceiver pin measurement shows the level delivered. If temperature cycling occasionally changes the mode, compare both voltages through the rail and startup transitions.
The nearby part numbers have different low-power behavior. The SN65HVD231 disables both directions when RS is high. The SN65HVD232 lacks that mode control. Matching the package and supply does not establish equivalence when a low-power board has to sense bus traffic. Record both the reception of a test signal and the first successful local transmission for each candidate.
Confirm bit time and slope after restoring the driver
The example controller takes its reference from a 16 MHz active oscillator. At a target 500 kbit/s, the nominal bit interval is 2 µs, equal to 32 reference periods. The actual controller can use prescalers and time-quanta settings. The arithmetic simply establishes the expected order of magnitude for the bus bit interval. Changing the reference or bit rate cannot replace driver enable in standby. Once transmission is enabled, check bit timing, dominant differential amplitude and available margin at the intended sampling time.
TI's example for slope control is about 15 V/µs near 10 kΩ and about 2 V/µs near 100 kΩ. For an idealized 1 V linear excursion those rates imply about 67 ns and 500 ns. Those estimates show where to look on a capture. Use propagation specifications and actual receiver crossings for timing acceptance. Include the specified wiring and termination on the bench and inspect the stable interval at the far node.
For sample acceptance on a 16 MHz active oscillator board, record the reference, default and active RS levels, and the first and subsequent frames with the specified termination. Run the same case at cold start, after sleep and after reset, and record whether the other node acknowledged. When the board drives the bus but gets no acknowledgment, investigate the receiver and protocol conditions. If even the local dominant bit is absent, keep working along the drive path. The saved data then gives a clear comparison for a revised board or alternate transceiver.