Two AD7768-1 converters share a 16.384 MHz active oscillator and produce data at the same rate. After a filter change both receive synchronization, yet the controller sometimes assigns an old sample from one device to the new batch. The critical evidence is sync at each converter and the adjacent data-ready edge. The data sheet warns that a late synchronization can leave an imminent DRDY pulse visible.
Verify sync at the pins relative to the shared clock
Analog Devices requires synchronization after power-up and configuration changes. In a multi-device system the initiating converter can produce an MCLK-synchronous SYNC_OUT, routed back to its SYNC_IN and to the other converters. The recommended placement is shortly after DRDY. If sync is too close to the next DRDY pulse, it may not propagate internally in time to suppress that old notification. The host's command log alone cannot establish what each device accepted.
Trace the shared 16.384 MHz oscillator to both MCLK pins and verify continuous, compatible clocks. Observe each SYNC_IN close to the pin and correlate both DRDY signals. Where isolation or fanout adds unequal routes, measure the real receiving points rather than using the controller's output time. Deskew the instrument channels with the same signal before treating a small difference as board delay.
For scale, configure a fast-mode converter with 16.384 MHz MCLK and divide by two, giving 8.192 MHz modulator frequency. At a Sinc5 decimation ratio of 256, output rate is 32,000 samples per second, or 31.25 microseconds per sample. This establishes the data period. Any filter settling time after resynchronization must still be evaluated for the actual configuration. Discarding one word is not a universal release rule.
Use one input to identify a sample-index error
Apply the same in-range test sine wave to both analog paths. Record their baseline relative phase at fixed settings. A four-kilohertz input has a 250-microsecond period. A 31.25-microsecond sample delay is one eighth of that period. Pairing a sample with the preceding frame can therefore look like a 45-degree phase error. This is a sample-association error. It does not imply a matching propagation delay in the MCLK trace. At another input frequency, the frame interval stays the same but the phase angle changes proportionately.
In an engineering test, compare a sync shortly after DRDY with one close to the next data-ready edge, where an old notification can still appear. Record configuration writes, both sync waveforms, raw DRDY timestamps, and the first delivered sample indices. Identify whether either or both converters exhibit the old pulse. Restore the intended timing and repeat. Event counts demonstrate sensitivity without leaving the diagnostic timing in production.
The data reader must associate the word with the right notification. An old interrupt or queued result can survive a sync command. Mark or isolate unverified queued data before opening a fresh batch, and use one first-valid rule after both devices have met their settling conditions. Pair by acquisition event rather than host read order. Transport order and acquisition order are different.
With separate isolation or level translation, verify effective sync width too. Under a common trigger, measure each pin crossing and duration against the requirements. A slow pulse may look clear at the controller but leave a narrow valid interval at an ADC. Compare sync skew with the master-clock period to see whether edges straddle neighboring capture opportunities. A small propagation difference can matter at the boundary.
Repeat boundary checks after a reference substitution
Verify the analog test reference as well. Swap the two branches of the same analog source between runs and see whether the steady phase error follows the front end or the recorded sample. If a near-one-frame offset appears only at first-frame selection and disappears after correcting association, the capture pairing explains it. A sustained offset across an entire record requires checking both filters and analog paths before shifting data by one frame.
Log the source and filter settings used for the phase comparison. Recalculate the expected phase angle of a one-frame mismatch if the input frequency changes.
After changing to another 16.384 MHz active oscillator, measure both MCLK inputs, the sync route, and the first-frame rule. If the same fault follows a filter change with both references, fix synchronization and queue handling first. If temperature or edge rate affects which pulses are accepted, check the real input paths. Keep event waveforms across the failure and identify what qualifies the first usable pair. A fixed delay without a defined start cannot establish the alignment.