Two 20 MHz passive crystals fit the same board and have similar series resonance and motional resistance. An impedance sweep shows a lower-frequency high-impedance peak on the replacement. The peak depends on the crystal's electrode capacitance and on any residual fixture capacitance. One sweep cannot differentially identify those contributions. Adding a known capacitor across the port and repeating the sweep gives the model a second condition to explain.
Establish the two frequencies to track
Epson's equivalent circuit joins a motional resistance, inductance, and capacitance in a series branch, with static capacitance C0 across the terminals. The two motional reactances cancel near series resonance. Slightly higher in frequency, the inductive motional branch can cancel shunt susceptance and produce an impedance maximum. A specified loaded frequency uses other load conditions, so neither scan frequency automatically belongs in the nominal-frequency column.
Correct the measurement plane as specified for the instrument and fixture. Record fixture identification, excitation, and sweep spacing before moving parts. Close features need sufficiently dense frequency points. Keep impedance and phase or complex admittance. A noisy high-impedance region can produce an unstable peak fit even if the instrument reports a value. The Keysight E4990A four-element analysis returns motional and static capacitance and multiple characteristic frequencies. Verify the exported field definitions. A transmission minimum marked manually is not necessarily the series resonance needed in this calculation.
With low loss and an isolated primary resonance, square the ratio of antiresonance to motional series resonance, then subtract one. The result is approximately motional capacitance divided by total shunt capacitance. Suppose total shunt capacitance is 2.5 picofarads and the nominally 20 MHz passive crystal has antiresonance at 20.040 MHz relative to a 20 MHz series frequency. The calculated motional capacitance is about 10.01 femtofarads. The total may still include unremoved fixture capacitance beyond the reference plane. The first sweep alone cannot identify 2.5 picofarads as the part's value.
Apply a known change for the second sweep
Keep the same plane, crystal, and excitation. Sweep as installed, then add a one-picofarad capacitor characterized at the test frequency across the same endpoints. If the motional branch is unchanged, total shunt capacitance increases from 2.5 to 3.5 picofarads. The ideal model places the high-impedance peak near 20.02858 MHz, approximately 11.42 kilohertz closer to series resonance. On a one-hundred-hertz grid, the peak shift spans approximately 114 intervals, which helps distinguish it from a one-bin change.
The measurements can also be used to infer the original total shunt capacitance. Call the first squared frequency ratio minus one A and the second B. With motional capacitance fixed, the original total equals the added capacitance times B, divided by A minus B. The unrounded example yields 2.5 picofarads. Multiplying that total by A gives the motional capacitance. A small difference between A and B amplifies measurement errors. Increase frequency resolution or choose an adequately sized, characterized addition.
Provide a shunt location in the fixture instead of attaching the capacitor with long flying leads. Measure what the interchangeable position actually adds with an empty fixture and retain the value near the operating frequency. Using the capacitor marking alone misses changes from the pads, contacts, or attachment. Remove it at the end and verify that the peak returns to its original position. This also checks fixture contact repeatability.
Check that the same motional branch fits both sweeps. If fitted series resonance or motional resistance changes materially after adding the capacitor, investigate excitation at the crystal, connection geometry, and adjacent modes. The capacitor has losses and inductance of its own. The inferred capacitance is useful when the same motional branch explains both complex responses over the region of interest.
A third sweep with a different characterized capacitor gives an independent check. Predict the next peak from the first two sweeps before looking at the result. A discrepancy beyond uncertainty warrants checking additional shunt paths beyond the reference plane.
Let the change distinguish the part from the fixture
Repeat the paired sweeps on multiple 20 MHz passive crystals. Keep the measured peak movement and motional parameters separately. If many units shift together after a fixture change, check reference plane and empty-fixture capacitance first. If a reproducible feature follows one lot, retest it under the agreed definitions and fixture conditions. Verify frequency at the intended load if needed. An antiresonance peak does not replace the assembled circuit criterion.
Keep excitation, reference plane, both complex traces, measured added capacitance, and the model's frequency range in the inspection record. When purchasing only specifies frequency tolerance and maximum resistance, the paired result can still diagnose a substitution. A delivery limit for static capacitance needs an agreed method and uncertainty first. The controlled shunt change then remains useful without creating an extra source of disagreement between instruments.