Two 20 MHz crystals both measure 20 Ω ESR. Why check the slope around resonance?

Two 20 MHz crystals show the same series resonance and 20 Ω equivalent series resistance. A narrower sweep reveals that the phase changes faster on the second unit. The resistance describes its losses near resonance. The slope also depends on motional inductance. For designs that rely on narrow filtering, settling or a particular oscillator loop response, the additional measurement shows why equal resistance alone does not predict equal behaviour.

Fit the motional branch separately from the electrode capacitance

Epson models a crystal near resonance as a series motional branch with a shunt capacitance. The branch has a resistance, inductance and capacitance. Keysight's impedance analyzer documentation gives the corresponding four-element model and parameter names. Direct terminal impedance includes shunt capacitance and fixture residuals. Calibrate and extract the motional branch before using a phase slope. The observed terminal zero crossing can differ from the fitted motional series resonance.

Verify the reference plane with appropriate checks for a 20 MHz crystal. Apply the fixture calibration and use suitable verification standards at the sample. Keep crystal drive, temperature, sweep spacing and contact conditions fixed. If the finished board supports two drive settings, first establish a reference at the agreed component test drive. Drive changes can also alter measured resistance or frequency.

Start with a broad sweep to locate the main mode and check for neighbouring modes. Then take enough points on both sides of the narrow resonance. A feature only a few hundred hertz wide is easily missed by coarse spacing. Repeat selected points to check drift or contact variation and retain fit residuals. A one-sided error can indicate an unwanted mode, remaining delay or an unsuitable capacitance model, all of which deserve attention before interpreting the slope.

The same resistance can produce different quality factors

In a hypothetical test both units resonate at 20 MHz and have 20 Ω motional resistance. The first has 10 mH motional inductance and the second has 15 mH. Series branch Q is angular frequency times motional inductance divided by resistance, giving about 62,832 and 94,248. The second value is about 50% higher despite equal resistance.

Very close to series resonance the motional reactance slope is approximately four times pi times the motional inductance. At 100 Hz above resonance the two example branches give about +12.57 Ω and +18.85 Ω. The arctangent of reactance divided by 20 Ω gives about 32.1° and 43.3° of branch phase. Comparable offsets below resonance show the opposing phase swing. The raw terminal curve also includes shunt capacitance and need not show the same angles.

As a cross-check for a single series branch, the full half-power bandwidth is approximately frequency divided by Q. The examples give about 318 and 212 Hz. This applies to the isolated motional mode after accounting for fixture and shunt effects. It cannot be read unchanged from an arbitrary transmission notch. If bandwidth and fit disagree, verify drive power, bandwidth definition and interpolation before judging the parts.

Let the actual design determine the purchase requirement

If the project only specifies loaded frequency, ESR and drive for its 20 MHz crystals, use those contractual requirements. For a design sensitive to pulling, transients or phase noise, agree on motional parameter ranges and a test method. Higher Q can support narrowband selectivity. Board startup also depends on gain, oscillator load and tuning. The bare crystal's Q does not establish the assembled circuit's startup time.

Use a proven board to compare frequency, startup envelope and repeatability over the specified temperatures. Keep load and supply unchanged. If the fit differs but system behaviour is the same, preserve the device data without adding an unsupported production limit. If system behaviour changes alongside a verified motional parameter, obtain more lots and a matching method from the supplier before setting a reproducible product criterion.

Check whether the analyzer changes source level or intermediate-frequency bandwidth between samples. Record fixed conditions with the fit. If production needs wider point spacing for speed, compare it with a dense sweep on borderline samples and verify that fixture position does not cause misclassification. Retained raw complex data and standards help requalify the measurement after changes to cables, filters or software.

A small difference in resonance centers can also distort an overlay at fixed instrument frequencies. Plot frequency offset from each crystal's fitted series resonance to compare slopes on both sides. Retain the original absolute-frequency traces for tolerance checks. The two views answer different questions, and an offset plot can show where one edge of the narrower feature runs into a fixture artifact.

References

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.