A scanner selects several sensors through an ADG1208. Its host uses a 20 MHz active oscillator to time selection and sampling. Each channel reads steadily when left selected. Alternating between substantially different voltages biases the first point toward the previous channel, while later points settle. Measure the interval from multiplexer switching to conversion. Once the switch changes connections, the shared node and receiver still need to settle to the required precision.
Treat switching and settling as separate intervals
ADI specifies break-before-make and charge injection separately. The old channel disconnects before the new channel connects. That describes connectivity. It does not establish the output voltage to the final bit. Source impedance, on-resistance, interconnect capacitance and the receiving circuit affect settling. Charge injection can add a transient. Using a switch timing figure as the whole acquisition delay can miss a high-impedance channel.
Use two distinct voltages in range. Measure each channel after it settles, then alternate them and save the first two readings with the previous channel identified. If error changes direction with the step, inspect the settling tail along with charge injection and acquisition loading. If a fixed channel also drifts, revisit the source and conversion path before attributing everything to selection.
Derive a delay from the required error
For a first-order example, assume a full-scale step, total effective resistance of 2 kΩ and 60 pF at the node. The time constant is 120 ns. In a 12-bit system, a half-LSB settling target is 1/8192 of full scale. An ideal exponential needs ln(8192), about 9.01 time constants or 1.08 µs. This covers an idealized settling tail. Verify the switching interval, dynamic acquisition load and any other amplifier settling separately.
Suppose the 20 MHz active oscillator supplies a verified undivided timer. A tick is 50 ns. Round the 1.08 µs tail up to 22 ticks. Add a trial 200 ns budget before the tail begins and the combined estimate is about 1.28 µs, or 26 ticks rounded up to 1.30 µs. This is a conversion to timer units. Allow for clock error and the actual address and sampling edges, then validate the worst real input step.
Measure whether control or analog settling is late
Capture the final address edge, multiplexer output and conversion trigger. Updating address pins separately can temporarily select another channel. Check whether the port updates them together or whether enable can enforce the intended sequence. A fixed delay that hides an intermediate state on one board can fail when the implementation changes. The actual address boundary is more useful than a software call timestamp.
Start with a long delay and reduce it while comparing first-point error across channels. If only high-impedance sources need more time, retain both step directions and check loading. A fixed jump on every channel calls for checking trigger settings and sample ownership. Record probe capacitance or corroborate analog measurements with digital sample error, particularly on a high-impedance node.
Define full scale and the comparison method before judging half an LSB. At 2 V full scale it is about 0.244 mV. If individual readings already vary by that much, a single reading cannot isolate mean error due to selection. Repeat the same switch, record first-point mean and spread, and compare against the steady-channel baseline. Apply the actual product error requirement, including measurement noise.
In a trial adding another 60 pF, doubling the total capacitance doubles the modeled tail for the same error target. If behavior is very different, check for a slower amplifier, protection component or sampling capacitor. Record probe type and loading if the capture changes with the probe, so future measurements can be compared under the same conditions.
Use the real scan order and largest expected differential between adjacent channel values before acceptance. Check rapid switching and the first scan after waiting. If discarding a first point is part of the product, document the rule and recalculate effective output rate. Include the 20 MHz active oscillator specification, effective timer rate, selection-to-sample gap and allowed first-point error. Those records identify what must be recalculated after a clock, sensor or filter change.