A USB hub with a 24 MHz passive crystal has plausible supply and reset waveforms, yet the upstream host reports no attachment. A board revision without the configuration controller works. Check the hub's boot mode. In SMBus mode it waits for an explicit USB attach command. Oscillation makes the reference available, but firmware still has to complete configuration.
Identify the boot configuration
Microchip's data sheet and design checklist show that CFG_SEL1 low and CFG_SEL0 high select SMBus on the USB2514B. The hub waits as a slave for an external controller. Strap-default and EEPROM modes follow other startup paths. Check the fitted resistors and actual levels around reset. An idle-high bus in normal operation does not establish which configuration the hub sampled.
Capture RESET_N and CFG_SEL together with the first controller transaction. Use a low-loading measurement if probing the 24 MHz passive crystal. A known-good board and a valid bus response also help establish the current startup stage. If the controller was replaced, verify its power-up pin states and the pull-up supply.
Verify the entire block write
The seven-bit SMBus slave address is 0x2C. The transmitted address-plus-write byte is 0x58. Pass 0x2C to a host interface expecting the unshifted address. An instrument may display either form. If the address is not acknowledged, check representation, boot mode, reset, and pull-ups.
The hub accepts the documented block transaction format. A one-byte write to set USB_ATTACH in register 0xFF includes the address and write bit, register number, byte count of one, and data byte 0x01 when no other command bits are needed. Four bytes with an acknowledge clock each take 36 SCL periods. At 100 kHz that is about 360 microseconds before start and stop timing or software delays. A generic register write without the count can show only 27 clocks and still produce some acknowledgments. Decode all fields to verify that the expected command reached the device.
Microchip explains that USB_ATTACH initiates attachment and write-protects the internal configuration area. Complete and verify the required configuration first. Readback of key settings before attaching is more informative than attempting to rewrite protected fields afterward. Begin another comparison from a known reset state.
Verify attachment at the upstream port
After the write, observe VBUS_DET and the host-side attachment. The hub uses VBUS_DET in deciding when to assert its internal connect pull-up. Verify the intended connection for removable and permanently attached designs. With a complete command but no upstream action, examine detection and wiring. If the host sees an attachment but does not complete enumeration, inspect the following reset and USB traffic separately.
Record a cold start and a hub-only reset. The first exposes power-order issues and the second shows whether the controller reconfigures the hub after its reset. For revisions with the same 24 MHz passive crystal, retain the strap evidence, configuration transaction, and host enumeration with the same test host and cable. That makes a boot configuration or attach sequencing repair reproducible.
Put reset stabilization and upstream attachment on one timeline
The power-up timing diagram lists at least 1 µs of reset hold after supplies become valid, up to 500 µs for the hub stabilization interval, and a separate upstream connection debounce interval of at least 100 ms. Read each number against its own endpoints. Adding these intervals does not yield an enumeration deadline that applies to every host. For a product that must expose the hub within a few hundred milliseconds, map the host software's enumeration, the supply controller's reset release and the actual management-bus STOP to the same capture. Check upstream power with the real cable and the intended supply arrangement.
If a full reboot works and a hub-only reset fails, check that the management controller sends the configuration again. The hub reset may leave the management controller running, and initialization may be called only at whole-system boot. In this case, the 24 MHz passive crystal can resume oscillating and upstream voltage can remain valid, while the new attachment write never appears. Compare reset, management frames and host detection for three conditions: cold boot, a hub-only reset and unplugging and reinserting the upstream cable. This distinguishes a missing initialization pass from oscillator startup behavior.
A second intermittent cause is configuration written too early. Move the first management frame later in a controlled build while preserving both supply traces and reset in each capture. If the address receives no acknowledgment, isolate supply readiness and strap mode. If the whole frame is acknowledged but the port fails to attach, turn to its data byte, STOP and upstream state. Save the exact byte where acknowledgment was observed so another engineer can reproduce the conclusion.