The 24 MHz passive crystal on a USB3300 board is oscillating, and the interface output measures 60 MHz. Register reads still return zero or occasionally echo the command. Disconnect the external USB data cable and examine the parallel local interface without USB traffic. The PHY and link controller share a bidirectional data bus. Command acceptance, exchange of bus ownership and capture of the reply each have their own timing.
Read and write in the 60 MHz domain and skip the turnaround cycle
The manufacturer's synchronous interface section specifies transfer on rising edges of the interface clock. With DIR low, the link controller owns the bus. With DIR high, the PHY drives it. Each transition of DIR includes a full turnaround cycle in which neither side drives the bus. If a receiver counts that cycle as data, it may see the previous command or a zero from board bias. An analyzer showing a logic value does not establish that either device was driving it.
The 24 MHz passive crystal supplies the oscillator input reference. The parallel link uses the PHY's interface clock. Their nominal periods are 41.67 ns and 16.67 ns, respectively. A turnaround cycle uses the latter period. If the system controller has a separate clock domain, verify which domain samples the physical pins. A direction transition observed asynchronously followed by a guessed delay cannot determine reply validity.
The register-read diagram shows the link launching a command with DIR low and waiting for NXT to signal command acceptance. The PHY recognizes a read, asserts DIR and deasserts NXT. After turnaround it drives the register value. Once the link samples it, ownership passes back through another turnaround, and the link drives the idle command. Generic receive logic that accepts a byte only when both DIR and NXT are high can miss this register return. Qualify register responses and normal USB packet reception according to the state of the interface and the corresponding data-sheet waveform.
Use Scratch to test both the command and the bus
USB3300 has a Scratch register for tests that do not affect PHY operation. The base read and write address is 0x16. An immediate read encodes binary 11 in the two high bits and the address in the low six, giving 0xD6. The write form uses binary 10 and gives 0x96. Write 0x55 and read it back, then repeat with 0xAA. Complementary values are more revealing than repeated zeros when checking a stuck data line, incorrect ownership or a register that was never written.
The write has its own end handshake. The link presents data after acceptance and uses STP at the end of the write, followed by the specified idle command. A read returning the old value may be correct if the preceding write never completed. Verify the write command, accepted data and end condition before blaming the read. If the write is correct and the return matches the command byte, inspect both drivers' enables and the controller sampling edge.
Trigger on CLKOUT and record data, DIR, NXT and STP. In the illustrated read sequence, a five-period separation from command launch to link sampling works out to about 83.3 ns. The figure is an illustrated sequence and does not set a universal maximum reply latency. If capture memory is limited, repeat one simple read and add a diagnostic pulse at the receiving state machine's capture event. Aligning that pulse with the valid bus word shows whether the PHY omitted the data or the controller sampled on the wrong cycle.
On wake-up, check that the interface clock has resumed
If failure occurs only after suspend, check whether the low-power command stopped the interface clock as designed. The data sheet shows DIR asserted after the relevant write, with five further rising edges before the clock stops. On wake, verify the order in which the clock returns and bus ownership is released. Do not rerun the Scratch exercise until the interface is ready. A cold-boot pass and a wake-up failure warrant separate traces.
To resume, the controller first asserts STP. If it drops STP before DIR falls, the PHY interprets that action as a false resume and goes back to low power. Change only the STP hold logic in one bench run and check whether CLKOUT appeared and disappeared. The data sheet gives 2.25 ms typical and 3.5 ms maximum for the suspend recovery interval up to clock startup. That is far longer than the handful of cycles in a Scratch read. Use the appropriate recovery interval, then verify actual DIR release and return to the idle command. A controller-only reset while the PHY remains suspended is another way to test the default STP level and startup protection.
For a 24 MHz passive-crystal USB3300 board, retain the reference frequency, the 60 MHz interface clock, the two complementary Scratch results and the direction transitions. Once local reads and writes are reliable, an enumeration failure can be pursued on the upstream cable, VBUS detection or protocol state. If the Scratch read itself fails, fix and verify the parallel turnaround first.