An industrial acquisition board uses a 24 MHz active oscillator for its host and reads a sensor across an ADuM1250 isolator. Some prototypes acknowledge the address, while a change in environment or host unit brings frequent timeouts. Reducing I²C from 400 kHz to 100 kHz widens the waveform without clearing the error. With activity visible on both lines, measure the voltage at the host during the acknowledge bit. The two isolator sides have different low-level specifications, and a visible downward pulse can fall outside the host's guaranteed low input range.
Follow the acknowledge through the isolator
After the eight address and direction bits, the addressed device pulls SDA low during the ninth clock. A sensor attached to Side 2 pulls its local SDA down first. The isolator then drives Side 1 low with respect to the host ground. The host sees the isolator's Side 1 output. The sensor's own output voltage is relevant when checking whether Side 2 can receive its low. Using the sensor output figure for the host end skips a driver.
ADI's application note explains the offset at Side 1. On a bidirectional open-drain line, the input and output share a node. If every detected low simply held the remote side low, the isolator could keep seeing its own output after the external device released the line. The ADuM1250 separates its Side 1 low output level from the threshold used to recognize an external pulldown. A host connected on that side has to accept the resulting offset voltage.
Compare guaranteed output and input limits
Start with the 0.9 V maximum Side 1 low output. Suppose the host only guarantees a low input up to 0.8 V over the applicable supply and temperature range. The boundary margin is 0.8 − 0.9 = −0.10 V. Intermittent success on ten samples provides no guarantee for that pairing. A different host might specify its low input at 0.3 times supply. At 3.30 V, the 0.99 V input limit gives 90 mV at that operating point. At 3.0 V, if the ratio still applies, the input limit becomes 0.90 V and that margin is gone. Use the applicable guaranteed entries wherever the host data sheet specifies separate ranges.
The isolator's output maximum also comes with conditions. Check the actual supply range, pull-up network and loading. When a plateau is unexpectedly high, record what is pulling the line down, check for duplicate pull-ups outside the fixture and verify each side's supply and ground. A low during host transmission establishes how the host drives the line. During an acknowledge the host has released SDA and the isolator drives it. Label the two cases individually. A debug run with a push-pull pin cannot represent this open-drain exchange.
Slower I²C separates rise time from low-level margin
In this example the host clock tree uses the 24 MHz active oscillator as its reference. At a measured 400 kHz SCL, one period is 2.5 µs. At 100 kHz it is 10 µs, four times longer. The longer period may give a passive pull-up more time to charge the bus and move the sampling point. It does not inherently take a 0.9 V low plateau below 0.8 V. When overlaying waveforms, mark the middle of the acknowledge plateau, the actual SCL high interval and the last threshold crossing in the preceding data bit. This shows which portion changed when the rate was reduced.
Measure SDA and SCL against the local ground of each power domain. To capture both sides together, use a suitable isolated or differential setup and verify the instrument connections. Ground clips on an ordinary bench scope can bridge the isolation barrier. After the address acknowledge, include bursts, repeated starts and any clock stretching used by the actual peripherals. The ADuM1250 has two bidirectional channels. The ADuM1251 differs in its clock direction, so check whether a peripheral ever pulls SCL low before substituting it.
Retest both directions after changing the connection
If swapping the connection direction, check the host against Side 2, then verify the peripheral's input and output limits against Side 1. Both transaction directions have changed. Measure valid pulldowns initiated at both ends, record high and low levels and check rise time after release. Install the actual panel cable and production pull-ups where applicable. Added capacitance may show up primarily during the rising transition.
Some systems keep polling while one side loses power. Separate this case from DC margin with both supplies settled. First verify sufficient low-level margin during normal operation. Then exercise host-first startup, peripheral-first startup and supported single-domain resets. Check the first start and acknowledge after power returns. If the first transaction misbehaves on the next board revision, this record locates the error before or after the bus becomes ready.
Keep the 24 MHz active oscillator specification and measured SCL rate in the report alongside local supplies, pull-ups and input thresholds. Update the host input, isolator orientation and peripheral interface when parts change. The acceptance evidence should show low-level margin, valid timing and completed transfers together. A saved decoder row that only says ACK cannot show how much margin the board had.