Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / System Validation and Replacement

PCM1865 goes silent at 44.1 kHz. Does the 24.576 MHz active oscillator have to change?

An audio capture board uses a 24.576 MHz active oscillator for the system clock of a PCM1865 in slave mode. The processor supplies the bit and frame clocks. Capture works at 48 kHz, but changing to 44.1 kHz returns zeros. First check the relationship of all three clocks before and after the change. Each can be toggling while the ratios fail automatic detection. Another oscillator of the same frequency and output type cannot fix a configuration that no longer matches the input clocks.

Check the ratio of system clock to frame clock

TI's clock-error table lists acceptable SCK-to-LRCK ratios of 128, 256, 384, 512 and 768 for the lower sample-rate group when the detector is active. At 48 kHz a 24.576 MHz system clock is exactly 512 times the frame rate. At 44.1 kHz with the same SCK, the ratio is approximately 557.28. It is absent from the list, even though it falls between two supported numbers. The data sheet says the device waits and drives the audio output to zero for this error. Confirm that the detector is enabled and read device status along with the output.

Keeping a 512-times implementation at 44.1 kHz would require a 22.5792 MHz SCK. Switching the clock with its associated bit clock, or using another supported clock path, is a design decision. In an example with 64 bit clocks per frame, the bit clocks are 3.072 MHz at 48 kHz and 2.8224 MHz at 44.1 kHz. Even when BCK/LRCK is 64 in both modes, leaving SCK unchanged can still cause the error. Capture all three clocks and record both ratios in stable windows before and after the transition. Preserve the intervening raw trace as a separate record.

Allow time for the automatic reconfiguration

TI's example of changing from 48 to 44.1 kHz in automatic slave configuration calls for a gap in clocks and data of at least three BCK periods, then time to reconfigure after the new clocks appear. With 64 edges per old frame and a 3.072 MHz bit clock, three periods occupy about 0.977 microseconds. That describes the scale of the gap. The example separately gives approximately 100 microseconds for reconfiguration and describes a return with a zero-crossing ramp if enabled. Define whether measurement starts from the final old edge or the first usable new clock. Do not convert the example wait into a guaranteed worst-case mute time.

Firmware may update the frame clock while a separate bus command still controls the oscillator selection. Those interim clocks can each be valid at the pin and fail as a group. Capture the request, SCK, BCK, LRCK, and output data, then check the device state register on page zero. Compare pre- and post-transition ratios to establish which source was last to settle. Verify that the host does not treat zeros during recovery as content. A steady, nonzero analog test input makes it easier to distinguish receiver waiting from actual audio silence.

Match the oscillator plan to the operating modes

A product that serves only the 48 kHz family may retain 24.576 MHz throughout. Test that relationship and restart behavior. If an external link must support both rate families, list the actual source for every mode. TI describes slave operation with a PLL derived from BCK and a way to disable automatic detection for a nonstandard SCK design. Those choices require validation of the timing and recovery conditions that the detector would otherwise check. Hearing sound after disabling error detection does not establish correct conversion.

Start acceptance with sustained 48 kHz capture after cold startup. Retain data and clock relationships. Switch to 44.1 kHz and count the frames from valid new clocks to valid output, then switch back and check for a transient mute, duplicated samples, or alignment errors. Compare device frames with the host record so that downstream buffering cannot hide the delay. After a substitution, measure actual signal levels and readiness for the 24.576 MHz oscillator and repeat every supported switch.

For a diagnostic control, retain the old system clock while deliberately switching the frame rate with automatic detection enabled. Save the output and state, then switch the complete clock set correctly and repeat with the same analog input. If the failure and recovery follow the table, the ratio explains the silence. If the correct ratio still fails, retain the traces and investigate the clock gap and the host's reacquisition instead.

Some products explicitly flag transitional frames as invalid, while others buffer during recovery. Define which event counts as valid restart. Record the first nonzero output and the first block meeting the intended quality criterion. A legitimate sample can equal zero at a crossing, so combine the known stimulus, device state, and actual frame count instead of using a single value as the criterion.

References