Can one 25 MHz crystal and a CDCM61002 provide 125 MHz and 156.25 MHz at the same time?

A network board might require 125 MHz for one receiver and 156.25 MHz for another. A generator has two differential outputs and lists both frequencies. That sounds like one 25 MHz passive crystal could feed both. The CDCM61002 illustrates why the block diagram and the simultaneous output configuration matter as much as the list of supported frequencies.

Find where the outputs branch

The TI block diagram shows a single PLL and a shared output divider. The outputs branch after that divider and share the output format selection. With a 25 MHz reference the data sheet provides a 125 MHz example and a 156.25 MHz example, each for a different whole-device configuration. Two same-frequency loads can be a fit. A 125 MHz LVDS connection and a 156.25 MHz LVPECL connection require both independent frequencies and the appropriate electrical formats.

Look for the divider relative to the output branch point. An additional bypass connection, if present, may only provide the original reference frequency. Ask the manufacturer for a configuration that can deliver the two required rates at the same time rather than a list of rates supported one at a time.

Compute both data-sheet configurations

For 125 MHz from a 25 MHz source, TI lists a prescaler of 4, a feedback divider of 20 and an output divider of 4. The VCO runs at 25 × 20 × 4 = 2,000 MHz. Dividing it by the prescaler and output divider gives 2,000 ÷ 4 ÷ 4 = 125 MHz. In the 156.25 MHz example the settings are 3, 25 and 4. The VCO is 1,875 MHz and 1,875 ÷ 3 ÷ 4 = 156.25 MHz. The last divider has the same value in both examples. The shared PLL settings change.

For a separate illustration, suppose the reference is 20 ppm high at the operating condition. With the PLL locked at the intended fixed ratios, the two possible outputs would each retain roughly the same fractional frequency error, which amounts to 2,500 Hz at 125 MHz or 3,125 Hz at 156.25 MHz. This calculation applies to average rate. Assess loaded waveforms and phase noise over the receiver's specified ranges. The generator's typical jitter data at one test condition do not establish production performance in a different setup.

Check the reference and VCO ranges for the chosen divider settings. For example, retaining the second configuration and substituting a 24.8832 MHz source gives 24.8832 × 25 ÷ 4 = 155.52 MHz. TI lists that as a separate configuration. A coarse display may make both outputs look like “around 156 MHz.” Save sufficient digits, the actual reference and the part number to detect an incorrect crystal variant.

Test a mode change before enabling the receiver

A board sold in two mutually exclusive variants can use different strap resistors. Capture the strap configuration, output format, measured frequency and each receiver’s expected frequency in the acceptance record. Start unloaded for fault isolation if that helps, then verify loaded waveforms with both actual receiver routes installed.

The manufacturer instructs the designer to issue a reset when the PLL settings are changed, initiating recalibration. The outputs are off during reset. If a system must switch modes in use, verify whether the receivers tolerate the absent reference and what reset or relock sequence they require. Capture the configuration, generator reset and receiver readiness together. A stable waveform at the end of the switch cannot show the clock gap or prove the receiving chips ignored an invalid interval.

Give each branch its own result field in the test record and keep both receiver loads connected. If only one instrument is available, leave the other branch loaded and keep straps unchanged while moving the measurement connection. Record the actual levels and termination. This demonstrates the two requirements under one configuration instead of two separately correct snapshots.

Ask for both receiver conditions on the quote

For simultaneous independent rates, evaluate separate 125 MHz and 156.25 MHz active oscillators, or a generator with independent output settings that can synthesize the two rates together. State whether the receivers need a common reference or defined phase relationship, or whether two independent sources can drift separately. That requirement affects what purchasing can substitute.

Specify each connection’s exact frequency, output logic, load and termination on a separate line. If the design uses a 25 MHz passive crystal, include the generator’s oscillator and load requirements. If it uses a 25 MHz active oscillator as the reference, check the driver's level and the manufacturer's clock-input circuit. A full order code and the intended configuration then give engineering enough information to verify both connections.