A 25 MHz passive crystal keeps a CDCM6208 board running and the output frequency looks stable, yet the system occasionally resets. Host logs show lock at every poll. Probe the physical status line first. Its low pulse can fit between host reads and still be long enough to affect the reset circuit. This measurement concerns an event after stable operation. Capture the moment the circuit actually responds.
Identify the status source before setting up the trigger
The CDCM6208 can drive different signals on a status pin, such as PLL lock, loss of reference, or reference selection. Combining them makes a transition ambiguous. Following TI's guidance, report lock on one pin and use the second for the reference diagnostic relevant to the test. Confirm the status polarities. The data sheet gives a requirement for secondary-input enable when using loss-of-reference detection. If that condition is missing, capture the input externally or use a validated monitor to establish whether the reference disappeared.
The digital detector can detect cycle slips at the phase-frequency comparison and reports an unlock indication after its internal criterion is reached. TI gives an example where an approximately one-part-per-million comparison error produces occasional lows lasting about one thousand PFD update cycles. That error is at the PLL comparison. A 25 MHz passive crystal with a one-part-per-million initial tolerance does not by itself predict how often the status pulses, because the feedback loop follows the reference.
Estimate a capture interval using the actual divider configuration. Suppose the 25 MHz passive crystal reference is divided by five before the phase-frequency detector. Its update rate is five megahertz, or 200 nanoseconds per cycle. One thousand cycles last 200 microseconds. With a separate configuration updating at twenty-five megahertz, the illustration gives forty microseconds. Use these values to select trigger settings. They do not guarantee pulse widths or equivalent loop behavior across configurations.
Capture status and the actual reset in the same record
Trigger on the falling edge of lock status and connect another channel to the reset node the controller responds to. Include an accessible reference or affected output clock in the same record. On boards with separate power domains, check probe loading so the reset filter remains representative. See whether status leads reset and measure the delay. A pulse shaper or asynchronous latch can keep reset asserted after status recovers, so reset length alone does not show the initiating pulse duration.
A coverage estimate explains the apparent discrepancy. With one poll per millisecond and random relative phase, a 200-microsecond low has a twenty-percent chance of overlapping a sample and roughly an eighty-percent chance of being missed. For forty microseconds the chance of detection is about four percent. This estimate requires nearly uniform event phase. An event synchronized to the host service interval may be missed every time. Hardware timestamps, a validated pulse latch, or segmented capture with known rearm gaps provide more reliable evidence than additional prints.
Use one time axis to examine output behavior. Establish stable operation before the event, then look for a missing period, phase displacement, or smaller short-term error during the status pulse. A frequency counter's numerous displayed digits do not reveal what happened to a single edge. Check error counters or a controlled transfer into the actual load. That separates a status-induced reset from a clock failure that was present before reset.
When an afternoon run captures one event, report the elapsed time, acquisition gaps, and effective live observation time. Use a separate channel to apply a diagnostic signal of known duration and timing to verify that the trigger and capture path can see it. Then return to the actual status signal. Separate initial startup from settled operation, because lock status may normally be low before startup is complete. Comparing event counts against live observation times avoids treating normal startup transitions as steady-state faults.
Validate nuisance immunity and real loss response
If a short status pulse resets the system while the output remains usable, evaluate reset filtering or status handling. Set the allowable pulse width and the maximum alarm latency for real clock loss before choosing hardware filtering or a latched firmware policy. Apply a controlled reference interruption and a repeatable short diagnostic pulse, verifying timely reset in the first case and immunity in the second. The loop may briefly sustain output after actual input loss. Check on the board which indication captures the condition the system cares about.
Retain the status configuration, PFD rate, measured pulse duration, and simultaneous clock behavior. After substituting a same-frequency crystal, repeat under the same fixture, temperature, and loop setup and compare actual event rates. Simply purchasing tighter initial frequency tolerance neither identifies the pulse source nor proves the next real clock failure will trigger the correct response.