A communications board uses a CDCM61004 and a 25 MHz passive crystal. The original board feeds high-speed devices from differential outputs and management logic from the bypass output. A new revision selects LVDS. The high-speed clocks remain, but the management circuit no longer starts. Measure OSC_OUT at its real destination and check the output select pins. This part uses the same mode table to select differential format and decide whether bypass is available.
Follow the reference and synthesized paths separately
The crystal pins belong to the reference oscillator. The reference feeds both the synthesis path and, when selected, a CMOS output named OSC_OUT. The four universal clocks use the synthesis and divider chain. Working high-speed clocks do not establish that the bypass pin is driven. List the function and frequency of each test point and map it to the downstream device that uses it.
TI's output table lists four combinations for the two select pins. Both high selects LVPECL and enables OSC_OUT. High and low selects LVPECL with bypass disabled. Low and high selects LVDS, also with bypass disabled. Both low selects LVCMOS and bypass remains disabled. A board changed from both high to the LVDS combination therefore follows the table when its management reference disappears. Adjusting the crystal load cannot re-enable an output disabled by selection.
Put each expected frequency on a specific pin
With a 25 MHz passive crystal, choose the data sheet option with prescaler 4 and feedback divider 20. The VCO target is 25 × 4 × 20 = 2000 MHz, inside the specified VCO range. After prescaling it is 500 MHz. A common output divider of four gives 125 MHz. In a mode with bypass enabled, OSC_OUT still carries the 25 MHz reference. Their nominal periods are 8 ns and 40 ns. Correct high-speed period supports the synthesis check. Measure the management branch itself.
The settings come from hardware control pins. Confirm actual logic levels or component population on boards with assembly options. Use the correct termination and measurement conditions separately for LVPECL and LVDS. Matching frequency does not establish equivalent bias and impedance. Verify the electrical connection before making the bypass comparison.
Provide both required outputs at the architecture level
A design that needs 125 MHz LVDS and a separate 25 MHz logic reference cannot get both from the listed mode selections alone. Give the management reference a suitable clock or buffer path of its own, or select a device with independent bypass and output controls. If the original passive crystal connects directly to the synthesizer, do not connect a digital input to the crystal pin as a substitute. That would add capacitance and load to the oscillator and could affect startup and frequency.
Keep two functional captures. First show both reference and synthesis clocks in the original mode that enables bypass. Then show the high-speed LVDS clock and disabled bypass in the target mode. With the revised management reference connected, repeat cold starts and verify it sees a qualified clock before it starts. If a board also loses the synthesized outputs, check supplies, enable and reset separately. That finding falls outside the mode-table explanation for bypass alone.
If different receiving devices are fitted, document their voltage and termination before the redesign. The four high-speed outputs share format selection. One output cannot remain LVPECL while another independently becomes LVDS through those pins. Specify whether the probe is at the source or receiver. Verify the electrical interface before repeating the management cold start.
A development board may use a generator in place of the crystal and borrow its second output for management. That temporary reference disappears on the production assembly. Draw the actual connections for the generator, bypass and management input. Test cold start without lab support and save the clock at management reset release. If reset precedes the clock, verify whether the receiver recovers by itself instead of relying on a manual reset.
Record the 25 MHz passive crystal part, input arrangement, output selection, dividers and management clock source. Document bypass availability for each build option. For a same-frequency redesign with a different electrical interface, retest startup of each dependent circuit. The report can then identify where a divider is needed, where a particular interface is required and where the system needs a separate continuous reference.