A clock board uses a 25 MHz passive crystal as the Si5332 reference. It sends 156.25 MHz LVDS to one daughterboard and 100 MHz LVCMOS to another. The configuration names both frequencies and assigns different formats. On hardware, setting an adequate level for the low-voltage CMOS receiver makes the differential link unreliable. Programmable format and physical output supply are separate design choices. Start with the exact package.
Map the shared output supplies
Skyworks offers package variants with six, eight, and twelve differential outputs. On the 48-pin Si5332-GM3 used here, OUT3, OUT4, and OUT5 share VDDO2. OUT9 has its own VDDO4. All three drivers in the first group share the external supply at that one pin even if their programmed frequencies differ. Assigning LVDS to OUT3 does not turn a 1.8-volt VDDO2 into a 2.5-volt supply.
Clock arithmetic can still be compatible with the shared group. Suppose a group uses a 200 MHz internal source. Divide it by two for 100 MHz and by four for 50 MHz. The device offers integer output divisors from one through 63. This example explains why frequencies can share a group source, subject to the actual source and routing resources. The bank still cannot satisfy two inconsistent output supply requirements.
A correct frequency can coexist with unsuitable common mode
Skyworks specifies an LVDS common-mode range of 1.125 to 1.275 volts with 2.5 or 3.3 volts on VDDO, and 0.75 to 0.85 volts at 1.8 volts. Suppose a DC-coupled receiver accepts an input common mode between 1.05 and 1.35 volts. The first range fits. The second is at least 0.20 volts below the receiver's lower limit. A frequency or differential-only measurement could still show a 156.25 MHz waveform while missing the voltage of the two pins relative to ground.
If the other output in that bank needs 1.8-volt logic, simply moving the bank to 2.5 volts can exceed its receiver limits. The data sheet gives a CMOS high-level minimum of VDDO minus 0.3 volts at the stated load. These nominal supplies give 1.5 and 2.2 volts respectively. Check both the receiver's required logic threshold and its permitted input range. A board can have a healthy 25 MHz passive crystal and a poor electrical match at an output.
Reassign the pins and qualify the receivers
On this 48-pin example, the designer could leave 156.25 MHz LVDS on OUT3 with 2.5 volts on VDDO2. Move the low-voltage output to OUT9 and supply VDDO4 with 1.8 volts. Check the available clock routing, divider, output format, and termination for the reassigned pin. If the PCB cannot be changed, evaluate AC coupling with receiver-side bias or a suitable CMOS level translator. Then measure jitter and minimum pulse width on the resulting path.
On the first populated board, record VDDO for each group and frequency, swing, and common mode at each receiver. Probe both sides of a differential pair and verify CMOS levels and overshoot under the intended load. When comparing two 25 MHz passive crystal models, keep the Si5332 settings and output supplies fixed for the reference comparison. Preserve separate electrical evidence for an output that fails to toggle at the receiver.
Record the exact package and part number in the design handoff. Give each output a row for its actual VDDO pin and the receiver's permitted common-mode or logic range. Cross-check the installed resistors, rails, and receiver revision. This exposes an incompatible shared rail before layout and makes the board acceptance check reproducible.
Moving the output to another supply group can also change startup. The two rails may ramp differently and their outputs may become valid at different times. Capture both VDDO rails, the corresponding clocks, and receiver reset. A steady-state trace cannot show whether a receiver left reset too early. If standby requires removing power from a group, determine which other outputs share it and need to keep running. Distinguish a per-output enable change from removing a whole bank supply in the fixture script.
Consider two illustrative simultaneous voltage readings. At 1.38 and 1.02 volts the differential value is 0.36 volts and the common mode is 1.20 volts. At 0.98 and 0.62 volts the differential value is still 0.36 volts, but common mode is 0.80 volts. Only the first pair fits the hypothetical receiver range. Store common mode and frequency separately. Match the probe channels and align their timing so a differential transition is not computed from two different instants.
Use the actual loaded board for the electrical check. A replacement cable, a receiver with internal termination, or a different rail regulator changes the test conditions. Identify the output coupling and receiver revision associated with the result.