Can a 6.4 ppm reading identify the tolerance grade of a 25 MHz crystal?

A reel of 25 MHz passive crystals retains its lot marking but the order code is incomplete. Several room-temperature readings come within 10 ppm. That can establish conditions under which the measured specimens meet a narrow window. A device sold as ±20 ppm can also measure 6.4 ppm. Recover the order-code and lot relationship to identify what the supplier delivered. Use a documented measurement program if the project instead needs to screen the pieces on hand against a narrower internal limit.

Both grades share much of the same acceptance window

At 25 MHz, 1 ppm is 25 Hz. For the same room-temperature definition, ±10 ppm spans 24,999,750 to 25,000,250 Hz and ±20 ppm spans 24,999,500 to 25,000,500 Hz. Suppose sample A reads 24,999,840 Hz. Its −160 Hz offset equals −6.4 ppm, inside both. Sample B reads 25,000,320 Hz, or +12.8 ppm. Under valid conditions and sufficient measurement capability, it falls in the wider window but outside the narrower one. The reading does not identify B's ordering code. A nominal ±10 ppm device could be out of tolerance or could have been measured under the wrong conditions.

Check exported units and rounding. If a report stores MHz to three decimal places, its step is 1 kHz, or 40 ppm at 25 MHz. Both example values round to 25.000 MHz. Obtain native hertz readings, reference status, and the actual timing window. Display precision alone does not establish accuracy. If time is limited, prioritize reviewing units near a decision boundary while retaining counts and raw data.

Apply the manufacturer's definition and conditions

Epson's individual TSX-3225 X1E0000210605xx specification gives 25 MHz and an 18 pF load, with separate lines for 25 °C tolerance and temperature stability. Epson's FA-238 configuration guide likewise separates tolerance and temperature characteristic codes and lists ±20 ppm options. Confirm actual combinations from the full ordering item. A family configuration entry cannot identify a sample. Compare a 10 ppm quote and a 20 ppm quote only after confirming that both numbers describe the same property.

Set fixture load and drive to the exact specification. Use a known check device under equivalent conditions and verify temperature, fixture compensation, reference, and algorithm. Fixture changes affect the effective load. If suppliers specify different loads, measure each under its own defined conditions and independently compare system performance on the production board. Keep the fixture and system results identifiable.

Decide what evidence the reel needs

To establish identity, recover the original reel label, delivery paperwork, incoming photos, and cut-tape history. Ask the supplier for a code tied to the actual lot. If lots could be mixed, preserve positions and individual reads. Measurements from several samples cannot identify the rest of a reel.

If internal screening is authorized, define the room-temperature frequency check, the decision rule and its uncertainty, and retain each unit's result. Keep confirmed supplier identity, or its absence, visible alongside the internal test. Do not relabel screened units as another supplier order grade. Temperature stability, startup, electrical loss, and lifetime performance still require the applicable evidence.

Keep two fields in the record. One identifies the order item and supplier guarantee. The other identifies the specimen, measured conditions, frequency, and disposition. In this example −6.4 ppm documents overlap between two windows and +12.8 ppm flags the narrow limit for review. Neither result assigns a new part number. If documentation is recovered later, link it to the existing measurements.

First determine what screening serves. A narrower room-temperature window can leave more system margin, but it does not replace evidence at temperature, load, and assembly corners. Compare a fully identified reference part under the same assembly and system conditions. If the board supports trimming, retain results before and after adjustment and the clock-source settings. Otherwise a correction can conceal an incoming tolerance difference.

If rework moves frequency closer to nominal, check changed loading and temperature. Define whether the disposition uses a removed part, an installed part, or a reference fixture before comparing results. Keep the old check device when a new supplier lot arrives. For an apparent lot shift, review the raw distribution and traceability rather than picking the method that gives a more convenient value.