A control board performs normally but occasionally reconnects during a conducted immunity sweep. A counter still reports the 25 MHz oscillator within tolerance. A reading per second can conceal a few missing cycles. To locate the fault, determine where the waveform stops meeting receiver requirements. Observe both the oscillator output and the receiver with a setup that remains reliable under disturbance.
Set the RF stimulus and the board measurements separately
IEC 61000-4-6:2023 covers conducted disturbances induced by RF fields, ordinarily from 150 kHz to 80 MHz. The applicable product requirements and test plan determine the injection device, level and performance criteria. Rohde & Schwarz and Tekbox describe the coupling and decoupling network, which injects the disturbance into a selected cable and helps isolate the auxiliary equipment for reproducible tests.
Confirm the standard edition, level-setting method and port reference plane. Follow the laboratory process for establishing the injection level. When a reconnect occurs, log the port, excitation frequency, level, modulation and dwell. These are separate from the 25 MHz clock frequency. A failure reproduced during 17 MHz injection needs separate labels for stimulus and oscillator frequency. Keep harness routing, height, termination and grounding fixed when comparing candidate parts.
Check where the clock first fails
Observe the 25 MHz oscillator output and the actual receiver input using suitable short probe connections and reference points. Define valid edges using the receiver thresholds and minimum high and low times. Record processor reset, link recovery or fault latch on the same timeline. Once a sensitive frequency is found, hold or repeat that condition to capture the failure, then return to the full sweep to find any other sensitive bands.
A probe in an enclosure with a long harness can introduce a new common-mode path. Compare an approved isolated monitor and a run with board probes removed while leaving the rest of the setup fixed. Use an independent indication of interface failure. If the behaviour changes with probe placement, resolve the fixture effect first. A board status path or optically isolated monitor can help during this control.
If both observation points show missing edges, record the oscillator rail at its pins using an approved low-loop-area connection. Compare the timing of the rail disturbance and the output failure. Also run the same load, cables and trigger threshold without RF to rule out a periodic task or another ordinary event. If only the receiver fails its pulse-width requirement while the source remains compliant under its test load, check routing, receiver thresholds and return paths first.
Calculate why two missing edges barely affect an average
At 25 MHz the period is 40 ns. In a hypothetical record, rising edges would occur at 0, 40, 80 and 120 ns. If the receiver has no qualified rising edge between 0 and 120 ns, two expected edges are absent from this interval. If the disturbance occurs once in half a second, a simple count drops from 12,500,000 edges by two. The fractional change is 0.16 ppm, equivalent to about 4 Hz for that window. An actual counter's triggering, gate and statistics depend on its mode.
The same 120 ns gap could appear after a phase step, an interference pulse or a gap in the recording. Inspect successive waveform edges against qualified high and low times and verify that the reference channel is continuous. Use an independent clock for an external fault latch. A receiver monitoring time with the failed clock can miss the event entirely. Confirm continuous acquisition or known coverage before treating short interruptions as an acceptance measurement.
Compare three cases before reworking the board or replacing the oscillator
Compare the failing board with the RF applied, the same board without injection, and a matched control board under RF. When qualifying an alternate 25 MHz oscillator, keep board temperature, receiver mode, test level and harness constant. Install the candidate as specified. A temporary direct path or an external diagnostic source can narrow the search. After changing the clock route, qualify the actual assembly and connections intended for compliance testing.
Set the criteria in advance. If the equipment must maintain its receiver clock and link throughout the test, the two missing edges fail that condition even if the average frequency still meets tolerance. Where the product standard allows specified degradation and recovery, record the permitted effect and recovery interval. Keep the stimulus frequency, level, injection port and original receiver trace with the sweep report. Retest the known failure point first after a change, then run the full required band to check whether the problem was removed or shifted elsewhere.
If the event recurs at one stimulus frequency but varies in timing, record a marker synchronized to the modulation. Compare clock loss and subsequent reconnection against the modulation phase to see whether either clusters at higher disturbance amplitude. This aids localization while leaving the prescribed dwell and modulation settings in place. Use comparable observation coverage on every sample even if one shows no event at a particular phase.