An industrial gateway uses a DP83869HM with a 25 MHz active oscillator on XI. Its designer wants a network-recovered reference and divides the recovered clock down to about 25 MHz. A frequency display by itself cannot prove that the correct source is selected. The PHY can output a 25 MHz clock synchronous to XI by default, or generate a clock of the same nominal frequency from recovered timing. Identify the source first.

Distinguish the local reference, transmit clock and receive clock

The data sheet describes these clocks separately. An external crystal or oscillator provides the local reference. Transmit timing is related to that local clock. Receive timing is recovered from the physical link and follows the partner's transmit clock. CLK_OUT is synchronous to XI by default. On a gigabit receive channel it can instead provide nominal 125 MHz or divide it by five to 25 MHz. Their periods are 8 ns and 40 ns. The divided clock's nominal 40 ns period matches the local clock's. The important distinction is which source's frequency variation it follows.

A 25 MHz active oscillator drives XI according to the manufacturer input circuit. Leave the other crystal pin unconnected in that arrangement. The local reference is still required when the output selects recovered timing. A specification calling for 125 MHz at the recovered output does not change the XI frequency. If the downstream block only needs a local startup reference, check whether the default output meets that need. If it must track a different device's transmit timing, qualify the recovered clock against an established link and the system's validity conditions.

Read back the selection and link state, then compare frequency

The I/O configuration register at 0x170 contains the selection. For receive channel A on a gigabit copper link, selection zero uses the full rate and four divides by five. Default selection 0xC is synchronous to the local reference. Follow the same revision's prerequisite register setting before changing the selection, preserve other fields in the word and check the output-disable bit. Record the actual register readback, link speed and selected channel. An application write log misses settings later replaced by a reset or another driver.

Use a comparison whose expected difference is measurable. Suppose the local reference is measured at +10 ppm and the partner transmit reference at −20 ppm, with the stable recovered clock locked to the latter. The two available 25 MHz outputs differ by 30 ppm, or about 750 Hz. At 125 MHz the same relative difference represents 3,750 Hz. These are bench assumptions, not performance guarantees. Compare a buffered local observation point and CLK_OUT against the same calibrated timebase, then change to another compliant partner with a known frequency offset. A moving output and fixed local reference help establish recovered-clock selection.

Include cable removal and reconnection. If a frequency counter still reads approximately the expected value after disconnecting the cable, that does not show that the clock tracks a peer that is absent. Record link state, output frequency and when downstream logic accepts its reference. Requalify after the link returns. Keep operating link speed, traffic and recovery time with each trace. One steady-state display cannot describe those transitions.

Instrument resolution deserves its own check. For the example 750 Hz difference between two 25 MHz outputs, a 100 ms gate gives an expected difference of about seventy-five counts. With a 1 ms gate it is less than one count and can be lost to quantization or trigger uncertainty. This calculation helps select a bench measurement time. It still assumes an adequate instrument reference and no spurious extra edges. When changing partners, record its transmit reference and the resulting output measured at the same node, so the change can be distinguished from lab temperature drift.

A connector may also carry a second signal labeled 125 MHz. In a gigabit parallel interface, the transmit clock comes from the controller and the receive clock belongs to that data interface. Frequency alone does not identify either as the intended CLK_OUT signal for a synchronous system. Mark the physical pin in the schematic and record whether the test examines a local reference, line-side transmit timing or recovered receive timing. Check for mistakes at a header carrying multiple nominally identical frequencies.

Timing metrics differ between outputs. TI specifies default 25 MHz and recovered output timing separately. If downstream timing must follow the link, an oscillator's short-term jitter figure alone cannot qualify the entire recovery path. Retain separate traces under the same supply and temperature, with instrument bandwidth and the measurement method recorded. Avoid inferring a long-term metric from a single transient during reconfiguration. That separates part-level oscillator specifications from what the assembled recovery path actually delivers.

State how the reference will be used on the assembled board

If the first PHY clocks another device, TI gives a specific daisy-chain reset requirement. Avoid resetting the primary through its hardware reset pin and use the documented software path when a reset is needed. Record clock output across the tested reset so downstream failure does not get mistaken for oscillator stoppage. The sample record should identify the 25 MHz active oscillator at the local input and its levels, tolerance and connection. Also retain CLK_OUT selection, receive speed and requalification after reset. Matching the frequency is one requirement. Tracking the intended clock source confirms the routing.